Datasheet Exar XR33038ID-F — 数据表
制造商 | Exar |
系列 | XR33032 / XR33035 / XR33038 |
零件号 | XR33038ID-F |
宽电源18 V耐压RS-485 / RS-422收发器
数据表
XR33032/35/38
WIDE SUPPLY 18V TOLERANT RS-485/RS-422 TRANSCEIVERS
FEBRUARY 2014 REV. 1.0.0 GENERAL DESCRIPTION
The XR33032/35/38 family of high performance half duplex RS-485 transceivers are optimized to operate over a wide range of supply voltage, from +2.8V to +5.5V. The analog bus pins can withstand direct shorts up to ±18V, and are protected against ESD events up to ±15kV. In an isolated application it may be more efficient to use a remote power supply rather than generating an isolated supply at every node. The XR33032/35/38 transceivers can operate with more than 2V IR drop in the cable when utilizing a remote 5V power supply. The transceivers draw less than 600µA, and typically only 300µA when idling with the receivers active. The receivers include full fail-safe circuitry, guaranteeing a logic-high receiver output when the receiver inputs are open, shorted, or undriven. The receiver input impedance is 96k (1/8 unit load), allowing up to 256 devices on the bus while preserving the full signal margin. The drivers are protected by short circuit detection as well as thermal shutdown, and maintain high impedance in shutdown or when powered off. The XR33032 and XR33035 drivers are slew limited for reduced EMI and error-free communication over long or unterminated data cables. The DE and RE pins include hot swap circuitry to prevent false transitions on the bus during power-up or live insertion, and can enter a low current shutdown mode (40nA typically) for extreme power savings. FEATURES +2.8V to +5.5V Operating Range ±18V Fault Tolerance on Analog Bus pins Robust ESD (ElectroStatic Discharge) Protection: ±15kV IEC 61000-4-2 Air Gap Discharge ± 8kV IEC 61000-4-2 Contact Discharge ±15kV Human Body Model ± 4kV Human Body Model on non-bus pins 300µA Idle Current, 40nA Shutdown Current Enhanced Receiver Fail-Safe Protection for Open,
Shorted, or Terminated but Idle Data Lines Hot-Swap Glitch Protection on DE and RE Pins Driver Short Circuit Current Limit and Thermal
Shutdown for Overload Protection 1/8th Unit Load Allows up to 256 Devices on Bus Industry Standard 8 NSOIC Half Duplex Package TYPICAL APPLICATIONS Isolated Multipoint RS-485 Data Buses Remote Nodes Powered by the Host Building Automation and HVAC Industrial Process Control Networks Remote Utility Meter Reading Energy Monitoring and Control RO RE DE DI 1 2 3 4 R 8 7 6 VCC B/Z A/Y GND D 5 Exar Corporation 48720 Kato Road, Fremont CA, 94538 (510) 668-7000 FAX (510) 668-7017 www.exar.com XR33032/35/38
WIDE SUPPLY 18V TOLERANT RS-485/RS-422 TRANSCEIVERS
REV. 1.0.0 ABSOLUTE MAXIMUM RATINGS
These ar …
价格
模型线
- XR33032ID-F XR33032IDTR-F XR33035ID-F XR33035IDTR-F XR33038ID-F XR33038IDTR-F
其他名称:
XR33038IDF, XR33038ID F