Datasheet Texas Instruments SN65HVD22DRG4 — 数据表
制造商 | Texas Instruments |
系列 | SN65HVD22 |
零件号 | SN65HVD22DRG4 |
扩展共模RS-485收发器8-SOIC -40至85
数据表
SN65HVD2x Extended Common-Mode RS-485 Transceivers datasheet
PDF, 1.3 Mb, 修订版: F, 档案已发布: Nov 18, 2016
从文件中提取
价格
状态
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes |
打包
Pin | 8 |
Package Type | D |
Industry STD Term | SOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 2500 |
Carrier | LARGE T&R |
Device Marking | VP22 |
Width (mm) | 3.91 |
Length (mm) | 4.9 |
Thickness (mm) | 1.58 |
Pitch (mm) | 1.27 |
Max Height (mm) | 1.75 |
Mechanical Data | 下载 |
参数化
Common Mode Range | -20 to 25 |
Duplex | Half |
Fail Safe | Idle,Open,Short |
Fault Protection | -27 to 27 V |
HBM ESD | 16 kV |
ICC(Max) | 9 mA |
IEC 61000-4-2 Contact | N/A +/- kV |
Isolated | No |
No. of RX | 1 |
No. of TX | 1 |
Number of Nodes | 256 |
Operating Temperature Range | -40 to 85 C |
Package Group | SOIC |
Rating | Catalog |
Signaling Rate(Max) | 0.5 Mbps |
Supply Voltage(s)(Nom) | 5 V |
生态计划
RoHS | Compliant |
设计套件和评估模块
- Evaluation Modules & Boards: SN65HVD22EVM
SN65HVD22EVM Evaluation Module
Lifecycle Status: Active (Recommended for new designs) - Evaluation Modules & Boards: RS485-HF-DPLX-EVM
RS-485 Half-Duplex Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
应用须知
- RS-485 at 230-kbps Over Uncontrolled InterconnectPDF, 408 Kb, 档案已发布: Apr 12, 2004
This application report presents an evaluation of the SN65LBC184, SN65HVD22, and MAX487 transceivers in an uncontrolled impedance interconnection signaling at 230 kbps. The network used for the evaluation was identified as typical of that for building security. - RS-485 for Digital Motor Control ApplicationsPDF, 180 Kb, 档案已发布: May 12, 2003
This application report focuses on the benefits of using RS-485 signaling for motor control and motion control applications. This technology has several benefits for these applications in terms of noise immunity, wide common-mode voltage range, adequate data rate, and multipoint capability. Other applications also use RS-485 signaling to take advantage of these same benefits. Applications such as - The RS-485 Unit Load and Maximum Number of Bus ConnectionsPDF, 197 Kb, 档案已发布: Mar 15, 2004
The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.
模型线
系列: SN65HVD22 (6)
- SN65HVD22D SN65HVD22DG4 SN65HVD22DR SN65HVD22DRG4 SN65HVD22P SN65HVD22PE4
制造商分类
- Semiconductors > Interface > RS-485/RS-422