Datasheet Texas Instruments OPA3684IDR — 数据表

制造商Texas Instruments
系列OPA3684
零件号OPA3684IDR
Datasheet Texas Instruments OPA3684IDR

具有禁用的14-SOIC -40至85的低功耗,三路电流反馈运算放大器

数据表

Low-Power, Triple Current Feedback Operational Amplifier with Disable datasheet
PDF, 1.3 Mb, 修订版: C, 档案已发布: Jul 2, 2008
从文件中提取

价格

状态

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

打包

Pin14
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY2500
CarrierLARGE T&R
Device MarkingOPA3684
Width (mm)3.91
Length (mm)8.65
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical Data下载

参数化

2nd Harmonic67 dBc
3rd Harmonic70 dBc
@ MHz5
Acl, min spec gain1 V/V
Additional FeaturesShutdown
ArchitectureBipolar,Current FB
BW @ Acl210 MHz
CMRR(Min)53 dB
CMRR(Typ)60 dB
GBW(Typ)210 MHz
Input Bias Current(Max)10000000 pA
Iq per channel(Max)1.8 mA
Iq per channel(Typ)1.7 mA
Number of Channels3
Offset Drift(Typ)12 uV/C
Operating Temperature Range-40 to 85 C
Output Current(Typ)120 mA
Package GroupSOIC
Package Size: mm2:W x L14SOIC: 52 mm2: 6 x 8.65(SOIC) PKG
Rail-to-RailNo
RatingCatalog
Slew Rate(Typ)820 V/us
Total Supply Voltage(Max)12 +5V=5, +/-5V=10
Total Supply Voltage(Min)5 +5V=5, +/-5V=10
Vn at 1kHz(Typ)3.7 nV/rtHz
Vn at Flatband(Typ)3.7 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)3.5 mV

生态计划

RoHSCompliant

设计套件和评估模块

  • Evaluation Modules & Boards: DEM-OPA368XDBQ
    OPA368x Evaluation Fixture
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: DEM-OPA368XD
    DEM-OPA368xD: Demonstration board
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: DEM-OPA-SO-3B
    DEM-OPA-SO-3B
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: DEM-OPA-SSOP-3B
    DEM-OPA-SSOP-3B
    Lifecycle Status: Active (Recommended for new designs)

应用须知

  • Current Feedback Amplifiers: Review, Stability Analysis, and Applications
    PDF, 53 Kb, 档案已发布: Nov 20, 2000
    The majority of op amp circuits are closed-loop feedback systems that implement classical control theory analysis. Analog designers are comfortable with Voltage FeedBack (VFB) op amps in a closed-loop system and are familiar with the ideal op amp approximations feedback permit. This application bulletin will demonstrate how CFB op amps can be analyzed in a similar fashion. Once the closed-loop sim
  • Stabilizing Current-Feedback Op Amps While Optimizing Circuit Performance
    PDF, 280 Kb, 档案已发布: Apr 28, 2004
    Optimizing a circuit design with a current-feedback (CFB) op amp is a relatively straightforward task, once one understands how CFB op amps achieve stability. This application note explains a 2nd-order CFB model so that any designer can better understand the flexibility of the CFB op amp. This report also discusses stability analysis, the effects of parasitic components due to PCBs, optimization
  • Active filters using current-feedback amplifiers
    PDF, 227 Kb, 档案已发布: Feb 25, 2005
  • Expanding the usability of current-feedback amplifiers
    PDF, 215 Kb, 档案已发布: Feb 28, 2005
  • Noise Analysis for High Speed Op Amps (Rev. A)
    PDF, 256 Kb, 修订版: A, 档案已发布: Jan 17, 2005
    As system bandwidths have increased an accurate estimate of the noise contribution for each element in the signal channel has become increasingly important. Many designers are not however particularly comfortable with the calculations required to predict the total noise for an op amp or in the conversions between the different descriptions of noise. Considerable inconsistency between manufactu
  • Tuning in Amplifiers
    PDF, 44 Kb, 档案已发布: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, 档案已发布: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, 档案已发布: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

模型线

制造商分类