Datasheet Texas Instruments UCC28510DW — 数据表
制造商 | Texas Instruments |
系列 | UCC28510 |
零件号 | UCC28510DW |
先进的PFC / PWM组合控制器20-SOIC -40至105
数据表
价格
状态
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes |
打包
Pin | 20 |
Package Type | DW |
Industry STD Term | SOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 25 |
Carrier | TUBE |
Device Marking | UCC28510DW |
Width (mm) | 7.5 |
Length (mm) | 12.8 |
Thickness (mm) | 2.35 |
Pitch (mm) | 1.27 |
Max Height (mm) | 2.65 |
Mechanical Data | 下载 |
参数化
Control Method | CCM |
Device Type | PFC+PWM |
Operating Supply Current | 4 mA |
Operating Supply(Max) | 18 V |
Operating Temperature Range | -40 to 105 C |
Package Group | SOIC |
Package Size: mm2:W x L | 20SOIC: 132 mm2: 10.3 x 12.8(SOIC) PKG |
Peak Output Sink Current Gate Drive | 3 A |
Peak Output Source Current Gate Drive | -2 A |
Practical Operating Frequency(Max) | 0.5 MHz |
Rating | Catalog |
Special Features | Average Current Mode,Enable,OVP |
Startup Current | 0.1 mA |
UVLO Thresholds On/Off | 16/10 V |
生态计划
RoHS | Compliant |
设计套件和评估模块
- Evaluation Modules & Boards: UCC28521EVM
UCC28521 Evaluation Module
Lifecycle Status: Active (Recommended for new designs) - Evaluation Modules & Boards: UCC28514EVM
UCC28514 Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
应用须知
- UCC28517 100-W PFC power converter with 12-V, 8-W bias supply, Part 2PDF, 224 Kb, 档案已发布: Feb 28, 2005
To conclude the review of the UCC28517 PFC supply, this article covers the design of the second 12-V, 8-W power stage to be used as an auxiliary bias supply. - UCC28517 100-W PFC power converter with 12-V, 8-W bias supply, Part 1PDF, 202 Kb, 档案已发布: Feb 28, 2005
Power factor corrected (PFC) preregulators are generally used in ac/dc converters operating above 75 W or to meet line harmonic requirements. This article reviews the design of a 100-W ac/dc power stage with PFC. - Bootstrap Circuit for Green Mode ApplicationsPDF, 111 Kb, 档案已发布: Jan 27, 2006
- A New Synchronization Circuit for Power Converters (Rev. A)PDF, 209 Kb, 修订版: A, 档案已发布: Apr 21, 2010
The synchronization of multiple PWM and PFC controllers is desirable for many reasons. The most common reason is that it keeps all the noise at one particular frequency and makes it easier to filter. The circuit described changes the slope of the ramp to lock the converter’s switching frequency to an applied signal by a phase locked loop turning it into a voltage controlled oscillator. Furthermore - Startup Current transient of the Leading Edge Triggered PFC ControllersPDF, 43 Kb, 档案已发布: Jun 30, 2004
- Avoiding Audible Noise at Light Loads When Using Leading Edge Triggered PFC Con (Rev. C)PDF, 57 Kb, 修订版: C, 档案已发布: Apr 13, 2011
This application note applies to the TI average current mode, leading edge modulation PFC controllers. See Applicable Device Table for part numbers.
模型线
系列: UCC28510 (2)
- UCC28510DW UCC28510N
制造商分类
- Semiconductors > Power Management > Offline and Isolated DC/DC Controllers and Converters > Power Factor Correction