Datasheet Texas Instruments OPA2336PG4 — 数据表

制造商Texas Instruments
系列OPA2336
零件号OPA2336PG4
Datasheet Texas Instruments OPA2336PG4

单电源,MicroPower CMOS运算放大器MicroAmplifier系列8-PDIP -40至85

数据表

OPA336, 2336, 4336: Single-Supply, microPower CMOS Op Amp microAmplifier Series datasheet
PDF, 1.7 Mb, 修订版: C, 档案已发布: Jan 11, 2005
从文件中提取

价格

状态

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

打包

Pin8
Package TypeP
Industry STD TermPDIP
JEDEC CodeR-PDIP-T
Package QTY50
CarrierTUBE
Device MarkingOPA2336P
Width (mm)6.35
Length (mm)9.81
Thickness (mm)3.9
Pitch (mm)2.54
Max Height (mm)5.08
Mechanical Data下载

参数化

Additional FeaturesN/A
ArchitectureCMOS
CMRR(Min)76 dB
CMRR(Typ)86 dB
GBW(Typ)0.1 MHz
Input Bias Current(Max)10 pA
Iq per channel(Max)0.032 mA
Iq per channel(Typ)0.02 mA
Number of Channels2
Offset Drift(Typ)1.5 uV/C
Operating Temperature Range-40 to 85 C
Output Current(Typ)5 mA
Package GroupPDIP
Package Size: mm2:W x LSee datasheet (PDIP) PKG
Rail-to-RailIn to V-,Out
RatingCatalog
Slew Rate(Typ)0.03 V/us
Total Supply Voltage(Max)5.5 +5V=5, +/-5V=10
Total Supply Voltage(Min)2.3 +5V=5, +/-5V=10
Vn at 1kHz(Typ)40 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)0.125 mV

生态计划

RoHSCompliant

应用须知

  • Precision Absolute Value Circuits
    PDF, 100 Kb, 档案已发布: Oct 2, 2000
    You can build a precision absolute value circuit using two op amps and two precision resistors. If you use an op amp and an IC difference amplifier no user supplied precision resistors or resistor adjustments are required. Circuits shown are suitable for precision split supply operation and for single-supply operation. When used with a rail-to-rail op amp the single supply circuit can approach a
  • Tuning in Amplifiers
    PDF, 44 Kb, 档案已发布: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, 档案已发布: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, 档案已发布: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

模型线

制造商分类

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps