Datasheet Texas Instruments SN65LBC184DG4 — 数据表

制造商Texas Instruments
系列SN65LBC184
零件号SN65LBC184DG4
Datasheet Texas Instruments SN65LBC184DG4

集成了瞬态电压抑制功能的RS-485收发器8-SOIC -40至85

数据表

SNx5LBC184 Differential Transceiver With Transient Voltage Suppression datasheet
PDF, 1.1 Mb, 修订版: I, 档案已发布: Jun 30, 2015
从文件中提取

价格

状态

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

打包

Pin8
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY75
CarrierTUBE
Device Marking6LB184
Width (mm)3.91
Length (mm)4.9
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical Data下载

参数化

Common Mode Range-7 to 12
DuplexHalf
Fail SafeOpen
Fault Protection-15 to 15 V
HBM ESD15 kV
ICC(Max)25 mA
IEC 61000-4-2 Contact30 +/- kV
IsolatedNo
No. of RX1
No. of TX1
Number of Nodes128
Operating Temperature Range-40 to 85 C
Package GroupSOIC
RatingCatalog
Signaling Rate(Max)0.25 Mbps
Supply Voltage(s)(Nom)5 V

生态计划

RoHSCompliant

应用须知

  • RS-485 at 230-kbps Over Uncontrolled Interconnect
    PDF, 408 Kb, 档案已发布: Apr 12, 2004
    This application report presents an evaluation of the SN65LBC184, SN65HVD22, and MAX487 transceivers in an uncontrolled impedance interconnection signaling at 230 kbps. The network used for the evaluation was identified as typical of that for building security.
  • RS-485 for Digital Motor Control Applications
    PDF, 180 Kb, 档案已发布: May 12, 2003
    This application report focuses on the benefits of using RS-485 signaling for motor control and motion control applications. This technology has several benefits for these applications in terms of noise immunity, wide common-mode voltage range, adequate data rate, and multipoint capability. Other applications also use RS-485 signaling to take advantage of these same benefits. Applications such as
  • RS-485 for E-Meter Applications (Rev. A)
    PDF, 311 Kb, 修订版: A, 档案已发布: Aug 6, 2004
    This application report discusses the best practices for designing energy meter communication circuits using the RS-485 standard. Component selection and performance tradeoffs are covered with reference to relevant standards such as IEC 61036 and DL/T 645. Reference design details are provided to help energy meter engineers successfully complete their own circuit designs.
  • The RS-485 Unit Load and Maximum Number of Bus Connections
    PDF, 197 Kb, 档案已发布: Mar 15, 2004
    The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.

模型线

制造商分类

  • Semiconductors > Interface > RS-485/RS-422