Datasheet Texas Instruments TPS62050DGSR — 数据表

制造商Texas Instruments
系列TPS62050
零件号TPS62050DGSR
Datasheet Texas Instruments TPS62050DGSR

采用MSOP-10 10-VSSOP的可调800mA,10V Vin,95%高效降压转换器-40至85

数据表

TPS6205x 800-mA Synchronous Step-Down Converter datasheet
PDF, 1.1 Mb, 修订版: F, 档案已发布: Jun 26, 2015
从文件中提取

价格

状态

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

打包

Pin10
Package TypeDGS
Industry STD TermVSSOP
JEDEC CodeS-PDSO-G
Package QTY2500
CarrierLARGE T&R
Device MarkingBFM
Width (mm)3
Length (mm)3
Thickness (mm)1.02
Pitch (mm).5
Max Height (mm)1.07
Mechanical Data下载

参数化

Control ModeVoltage Mode
Duty Cycle(Max)100 %
Iout(Max)0.8 A
Iq(Typ)0.012 mA
Operating Temperature Range-40 to 85 C
Package GroupVSSOP
RatingCatalog
Regulated Outputs1
Special FeaturesEnable,Frequency Synchronization,Light Load Efficiency,Power Good,Synchronous Rectification
Switching Frequency(Max)1200 kHz
Switching Frequency(Min)600 kHz
TypeConverter
Vin(Max)10 V
Vin(Min)2.7 V
Vout(Max)6 V
Vout(Min)0.7 V

生态计划

RoHSCompliant

设计套件和评估模块

  • Evaluation Modules & Boards: TPS62052EVM-234
    TPS62052 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: TPS62050EVM-234
    TPS62050 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

应用须知

  • Maximum Output Current of TPS62050
    PDF, 51 Kb, 档案已发布: Mar 19, 2003
    The TPS62050 is a highly integrated synchronous step-down dc/dc converter capable of delivering output up to 800 mA. However, the maximum output current is limited by parameters such as ambient temperature, input-output voltage ratio, and switching frequency. This application report provides the maximum allowable output current of the TPS62050.
  • Adding Hysteresis to Low Battery Input on the TPS6205x (Rev. A)
    PDF, 89 Kb, 修订版: A, 档案已发布: Nov 28, 2007
    The low-battery input (LBI), available on several step-down converters, is often used to shut down the converter when the input voltage falls below a set threshold. This prevents damage to the battery and signals that the battery is at the end of its life and should be charged or replaced. Batteries have internal resistance that causes the voltage to drop as the load increases. This internal resis
  • Optimizing Resistor Dividers at a Comparator (Rev. A)
    PDF, 120 Kb, 修订版: A, 档案已发布: Jun 3, 2013
  • Design considerations for a resistive feedback divider in a DC/DC converter
    PDF, 393 Kb, 档案已发布: Apr 26, 2012
  • Optimizing Transient Response of Internally Compensated DC-DC Converters (Rev. A)
    PDF, 1.1 Mb, 修订版: A, 档案已发布: May 11, 2015
  • Five steps to a great PCB layout for a step-down converter
    PDF, 162 Kb, 档案已发布: Jan 29, 2015
  • Understanding the Absolute Maximum Ratings of the SW Node (Rev. A)
    PDF, 755 Kb, 修订版: A, 档案已发布: Jan 13, 2012
  • Testing tips for applying external power to supply outputs without an input volt
    PDF, 110 Kb, 档案已发布: Oct 24, 2016
  • Basic Calculation of a Buck Converter's Power Stage (Rev. B)
    PDF, 202 Kb, 修订版: B, 档案已发布: Aug 17, 2015
  • Extending the Soft Start Time Without a Soft Start Pin (Rev. B)
    PDF, 387 Kb, 修订版: B, 档案已发布: Jun 15, 2017
  • Choosing an Appropriate Pull-up/Pull-down Resistor for Open Drain Outputs
    PDF, 130 Kb, 档案已发布: Sep 19, 2011
  • IQ: What it is what it isn’t and how to use it
    PDF, 198 Kb, 档案已发布: Jun 17, 2011
  • Performing Accurate PFM Mode Efficiency Measurements (Rev. A)
    PDF, 418 Kb, 修订版: A, 档案已发布: Dec 11, 2018
    When performing measurements on DC-DC converters using pulse frequency modulation(PFM)or any power save mode proper care must be taken to ensure that the measurements are accurate. An accurate PFM mode efficiency measurement is critical for systems which require high efficiency at low loads such as in smart home systems tablets wearables and metering.

模型线

系列: TPS62050 (5)

制造商分类

  • Semiconductors > Power Management > Non-isolated DC/DC Switching Regulator > Step-Down (Buck) > Buck Converter (Integrated Switch)