Datasheet Texas Instruments TPS62102DG4 — 数据表
制造商 | Texas Instruments |
系列 | TPS62102 |
零件号 | TPS62102DG4 |
具有可调输出8-SOIC的多模1MHz同步降压转换器-40至85
数据表
价格
状态
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes |
打包
Pin | 8 |
Package Type | D |
Industry STD Term | SOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 75 |
Carrier | TUBE |
Device Marking | 62102 |
Width (mm) | 3.91 |
Length (mm) | 4.9 |
Thickness (mm) | 1.58 |
Pitch (mm) | 1.27 |
Max Height (mm) | 1.75 |
Mechanical Data | 下载 |
参数化
Control Mode | Voltage Mode |
Duty Cycle(Max) | 100 % |
Iout(Max) | 0.5 A |
Iq(Typ) | 0.164 mA |
Operating Temperature Range | -40 to 85 C |
Package Group | SOIC |
Rating | Catalog |
Regulated Outputs | 1 |
Special Features | Enable,Frequency Synchronization,Light Load Efficiency,Synchronous Rectification |
Switching Frequency(Max) | 1250 kHz |
Switching Frequency(Min) | 750 kHz |
Type | Converter |
Vin(Max) | 9 V |
Vin(Min) | 2.5 V |
Vout(Max) | 8 V |
Vout(Min) | 0.8 V |
生态计划
RoHS | Compliant |
设计套件和评估模块
- Evaluation Modules & Boards: TPS62102EVM
TPS62102EVM Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
应用须知
- Design considerations for a resistive feedback divider in a DC/DC converterPDF, 393 Kb, 档案已发布: Apr 26, 2012
- Optimizing Transient Response of Internally Compensated DC-DC Converters (Rev. A)PDF, 1.1 Mb, 修订版: A, 档案已发布: May 11, 2015
- Five steps to a great PCB layout for a step-down converterPDF, 162 Kb, 档案已发布: Jan 29, 2015
- Understanding the Absolute Maximum Ratings of the SW Node (Rev. A)PDF, 755 Kb, 修订版: A, 档案已发布: Jan 13, 2012
- Testing tips for applying external power to supply outputs without an input voltPDF, 110 Kb, 档案已发布: Oct 24, 2016
- Basic Calculation of a Buck Converter's Power Stage (Rev. B)PDF, 202 Kb, 修订版: B, 档案已发布: Aug 17, 2015
- Extending the Soft Start Time Without a Soft Start Pin (Rev. B)PDF, 387 Kb, 修订版: B, 档案已发布: Jun 15, 2017
- IQ: What it is what it isn’t and how to use itPDF, 198 Kb, 档案已发布: Jun 17, 2011
- Performing Accurate PFM Mode Efficiency Measurements (Rev. A)PDF, 418 Kb, 修订版: A, 档案已发布: Dec 11, 2018
When performing measurements on DC-DC converters using pulse frequency modulation(PFM)or any power save mode proper care must be taken to ensure that the measurements are accurate. An accurate PFM mode efficiency measurement is critical for systems which require high efficiency at low loads such as in smart home systems tablets wearables and metering.
模型线
系列: TPS62102 (2)
- TPS62102D TPS62102DG4
制造商分类
- Semiconductors > Power Management > Non-isolated DC/DC Switching Regulator > Step-Down (Buck) > Buck Converter (Integrated Switch)