Datasheet Texas Instruments UC3854DWTR-FG4 — 数据表
制造商 | Texas Instruments |
系列 | UC3854 |
零件号 | UC3854DWTR-FG4 |
高功率因数预调节器16-SOIC 0至70
数据表
价格
状态
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | No |
打包
Pin | 16 |
Package Type | DW |
Industry STD Term | SOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 2000 |
Carrier | LARGE T&R |
Device Marking | UC3854DW-F |
Width (mm) | 7.5 |
Length (mm) | 10.3 |
Thickness (mm) | 2.35 |
Pitch (mm) | 1.27 |
Max Height (mm) | 2.65 |
Mechanical Data | 下载 |
参数化
Approx. Price (US$) | 1.27 | 1ku |
Control Method | CCM |
Device Type | Single-phase PFC |
Operating Supply Current(mA) | 10 |
Operating Supply(Max)(V) | 30 |
Operating Temperature Range(C) | 0 to 70 |
Package Group | SOIC |
Package Size: mm2:W x L (PKG) | See datasheet (PDIP) |
Peak Output Sink Current Gate Drive(A) | 1 |
Peak Output Source Current Gate Drive(A) | -1 |
Practical Operating Frequency(Max)(MHz) | 0.2 |
Rating | Catalog |
Special Features | Average Current Mode Enable |
Startup Current(mA) | 1.5 |
UVLO Thresholds On/Off(V) | 16/10 |
生态计划
RoHS | Compliant |
Pb Free | Yes |
应用须知
- U-134 UC3854 Controlled Power Factor Correction Circuit DesignPDF, 346 Kb, 档案已发布: Sep 5, 1999
The UC1854 provides active power factor correction for power systems that otherwise would draw non-sinusoidal current from sinusoidal power lines. This device implements all the control functions necessary to build a power supply capable of optimally using available power-line current while minimizing line-current distortion. This application note describes the concepts and design of a boost prere - AC Requirements for Power Factor Correction CircuitsPDF, 29 Kb, 档案已发布: Mar 28, 2002
This technical brief identifies the recommended range of IAC for each of the devices within the UCC3854 family of PFC controllers. - DN-39E Optimizing Performance in UC3854 Power Factor Correction ApplicationsPDF, 277 Kb, 档案已发布: Sep 5, 1999
The performance of the UC3854 Power-Factor Correction IC in the 250W application example has been evaluated using a precision PFC/THD instrument. The result was a power factor of 0.999 and Total Harmonic Distortion (THD) of 3.81%, measured to the 50th line frequency harmonic at nominal line and full load. Users should get similar results at these conditions. as well as over most line and load rang - Accurate PWM Duty Cycle ClampPDF, 58 Kb, 档案已发布: Jan 25, 2002
Power supply applications using current sense transformers require a duty cycle clamp on the pulse width modulator (PWM) to ensure transformer reset. Not all PWMs come with a duty cycle clamp presenting a problem for the power supply designer. This application note shows how to implement a duty cycle clamp by using a simple delay circuit. - DN-41 Extend Current Transformer RangePDF, 37 Kb, 档案已发布: Sep 5, 1999
The problems with self reset of current transformers for unipolar pulse applications can be overcome with simple forced-reset techniques derived from magnetic amplifiers. Duty factors above 90% are achievable with these techniques. This design note describes a circuit configured for forced reset and a configuration that generates a negative voltage from the current transformer.