Datasheet Texas Instruments ADS1294 — 数据表
制造商 | Texas Instruments |
系列 | ADS1294 |
具有集成ECG前端的4通道,24位模数转换器
数据表
ADS129x Low-Power, 8-Channel, 24-Bit Analog Front-End for Biopotential Measurements datasheet
PDF, 2.5 Mb, 修订版: K, 档案已发布: Aug 7, 2015
从文件中提取
价格
状态
ADS1294CZXGR | ADS1294CZXGT | ADS1294IPAG | ADS1294IPAGR | |
---|---|---|---|---|
Lifecycle Status | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) |
Manufacture's Sample Availability | No | Yes | No | Yes |
打包
ADS1294CZXGR | ADS1294CZXGT | ADS1294IPAG | ADS1294IPAGR | |
---|---|---|---|---|
N | 1 | 2 | 3 | 4 |
Pin | 64 | 64 | 64 | 64 |
Package Type | ZXG | ZXG | PAG | PAG |
Industry STD Term | NFBGA | NFBGA | TQFP | TQFP |
JEDEC Code | S-PBGA-N | S-PBGA-N | S-PQFP-G | S-PQFP-G |
Package QTY | 1000 | 250 | 160 | 1500 |
Carrier | LARGE T&R | SMALL T&R | JEDEC TRAY (5+1) | LARGE T&R |
Device Marking | ADS1294 | ADS1294 | ADS1294 | ADS1294 |
Width (mm) | 8 | 8 | 10 | 10 |
Length (mm) | 8 | 8 | 10 | 10 |
Thickness (mm) | 1.01 | 1.01 | 1 | 1 |
Pitch (mm) | .8 | .8 | .5 | .5 |
Max Height (mm) | 1.45 | 1.45 | 1.2 | 1.2 |
Mechanical Data | 下载 | 下载 | 下载 | 下载 |
参数化
Parameters / Models | ADS1294CZXGR | ADS1294CZXGT | ADS1294IPAG | ADS1294IPAGR |
---|---|---|---|---|
# Input Channels | 4 | 4 | 4 | 4 |
Analog Voltage AVDD(Max), V | 5.25 | 5.25 | 5.25 | 5.25 |
Analog Voltage AVDD(Min), V | 2.7 | 2.7 | 2.7 | 2.7 |
Architecture | Delta-Sigma | Delta-Sigma | Delta-Sigma | Delta-Sigma |
Digital Supply(Max), V | 3.6 | 3.6 | 3.6 | 3.6 |
Digital Supply(Min), V | 1.65 | 1.65 | 1.65 | 1.65 |
INL(Max), +/-LSB | 8 | 8 | 8 | 8 |
Input Range(Max), V | 5.25 | 5.25 | 5.25 | 5.25 |
Input Type | Differential,Single-Ended | Differential,Single-Ended | Differential,Single-Ended | Differential,Single-Ended |
Integrated Features | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA |
Interface | SPI | SPI | SPI | SPI |
Multi-Channel Configuration | Simultaneous Sampling | Simultaneous Sampling | Simultaneous Sampling | Simultaneous Sampling |
Operating Temperature Range, C | -40 to 85,0 to 70 | -40 to 85,0 to 70 | -40 to 85,0 to 70 | -40 to 85,0 to 70 |
Package Group | NFBGA | NFBGA | TQFP | TQFP |
Package Size: mm2:W x L, PKG | 64NFBGA: 64 mm2: 8 x 8(NFBGA) | 64NFBGA: 64 mm2: 8 x 8(NFBGA) | 64TQFP: 144 mm2: 12 x 12(TQFP) | 64TQFP: 144 mm2: 12 x 12(TQFP) |
Power Consumption(Typ), mW | 3 | 3 | 3 | 3 |
Rating | Catalog | Catalog | Catalog | Catalog |
Reference Mode | Int,Ext | Int,Ext | Int,Ext | Int,Ext |
Resolution, Bits | 24 | 24 | 24 | 24 |
SNR, dB | 112 | 112 | 112 | 112 |
Sample Rate (max), SPS | 32KSPS | 32KSPS | 32KSPS | 32KSPS |
Sample Rate(Max), MSPS | 0.032 | 0.032 | 0.032 | 0.032 |
THD(Typ), dB | -98 | -98 | -98 | -98 |
生态计划
ADS1294CZXGR | ADS1294CZXGT | ADS1294IPAG | ADS1294IPAGR | |
---|---|---|---|---|
RoHS | Compliant | Compliant | Compliant | Compliant |
应用须知
- Thermal Noise Analysis in ECG ApplicationsPDF, 114 Kb, 档案已发布: May 3, 2011
This article discusses the thermal noise source of electrocardiogram (ECG) applications basedon the ADS1298 and ADS1298R family of multichannel, simultaneous sampling, 24-bit, delta-sigma (О”ОЈ) analog-to-digital converters (ADCs). This report offers several observations on identifying the major sources of thermal noise in an ECG system, and makes several recommendations regarding how to improve t - Respiration Rate Measurement Using Impedance PneumographyPDF, 697 Kb, 档案已发布: Mar 1, 2011
This document discusses the use of impedance pneumography as a technique to measure respiration rate. The generation of high-frequency ac current source is described, and the issues related to delay in modulated signal and finite transition times of carriers are addressed. The report also includesdescriptions of potential implementations of a respiration rate measurement system using the ADS1298 - Understanding Lead-Off Detection in ECG (Rev. A)PDF, 313 Kb, 修订版: A, 档案已发布: Jan 14, 2015
- Improving Common-Mode Rejection Using the Right-Leg Drive AmplifierPDF, 297 Kb, 档案已发布: Jul 6, 2011
This article discusses the need to improve common-mode rejection (CMR) in electrocardiogram (ECG) subsystem applications. Several different techniques to improve CMR while also considering both patient and operator safety are presented. This report also reviews the implementation of the right-leg drive (RLD) loop technique to improve CMR using the ADS129x family of analog-to-digital converters (in - Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)PDF, 191 Kb, 修订版: A, 档案已发布: Apr 13, 2010
This document discusses the characteristics of electrocardiogram (ECG) signals and different front-endapproaches for ECG signal acquisition. The tradeoffs between different approaches and the effects on overall system design are discussed. The report also includes descriptions of potential implementations of the front-end architecture using the ADS1258 and ADS1278 and respective noise measuremen - Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)PDF, 69 Kb, 修订版: A, 档案已发布: May 18, 2015
- A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)PDF, 425 Kb, 修订版: B, 档案已发布: Oct 9, 2011
This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference. - Principles of Data Acquisition and Conversion (Rev. A)PDF, 132 Kb, 修订版: A, 档案已发布: Apr 16, 2015
模型线
系列: ADS1294 (4)
制造商分类
- Semiconductors> Data Converters> Analog-to-Digital Converters (ADCs)> Precision ADCs (<=10MSPS)