Datasheet Texas Instruments DP83630 — 数据表

制造商Texas Instruments
系列DP83630
Datasheet Texas Instruments DP83630

精密PHYTER-IEEE 1588精密时间协议收发器

数据表

DP83630 Precision PHYTER - IEEE® 1588 Precision Time Protocol Transceiver datasheet
PDF, 1.4 Mb, 修订版: B, 档案已发布: Apr 15, 2013
从文件中提取

价格

状态

DP83630SQ/NOPBDP83630SQE/NOPBDP83630SQX/NOPB
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityYesNoYes

打包

DP83630SQ/NOPBDP83630SQE/NOPBDP83630SQX/NOPB
N123
Pin484848
Package TypeRHSRHSRHS
Industry STD TermWQFNWQFNWQFN
JEDEC CodeS-PQFP-NS-PQFP-NS-PQFP-N
Package QTY10002502500
CarrierLARGE T&RSMALL T&RLARGE T&R
Device MarkingDP83630SQDP83630SQDP83630SQ
Width (mm)777
Length (mm)777
Thickness (mm).75.75.75
Pitch (mm).5.5.5
Max Height (mm).8.8.8
Mechanical Data下载下载下载

参数化

Parameters / ModelsDP83630SQ/NOPB
DP83630SQ/NOPB
DP83630SQE/NOPB
DP83630SQE/NOPB
DP83630SQX/NOPB
DP83630SQX/NOPB
Cable Length, m150150150
Datarate, Mbps10/10010/10010/100
FunctionPHYPHYPHY
InterfaceMII,RMIIMII,RMIIMII,RMII
JTAG1149.1YesYesYes
Operating Temperature Range, C-40 to 85-40 to 85-40 to 85
Package GroupWQFNWQFNWQFN
Package Size: mm2:W x L, PKG48WQFN: 49 mm2: 7 x 7(WQFN)48WQFN: 49 mm2: 7 x 7(WQFN)48WQFN: 49 mm2: 7 x 7(WQFN)
Port CountSingleSingleSingle
RatingCatalogCatalogCatalog
Special FeaturesIEEE 1588 PTP,FX Support,Cable DiagnosticsIEEE 1588 PTP,FX Support,Cable DiagnosticsIEEE 1588 PTP,FX Support,Cable Diagnostics
Supply Voltage, Volt3.33.33.3

生态计划

DP83630SQ/NOPBDP83630SQE/NOPBDP83630SQX/NOPB
RoHSCompliantCompliantCompliant

应用须知

  • AN-1469 PHYTERВ® Design & Layout Guide (Rev. D)
    PDF, 289 Kb, 修订版: D, 档案已发布: Apr 26, 2013
    This application report describes PHYTERв„ў design and layout guidelines.
  • AN-1794 Using RMII Master Mode (Rev. A)
    PDF, 63 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    Texas Instruments PHYTERВ® family of products incorporate the Reduced Media Independent Interface (RMII) as described in the RMII revision 1.2 specification from the RMII Consortium. This interface may be used to connect a PHY device to a MAC in 10/100 Mb/s systems using a reduced number of pins relative to standard MII. In this mode, data is transferred two bits at a time using a 50 MHz refere
  • IEEE 1588 Precision Time Protocol Time Synchronization Performance (Rev. A)
    PDF, 609 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    This application report presents specific time synchronization results from the precision PHYTER.Histograms and oscilloscope plots of these synchronization results are provided, showing the relationshipbetween the slave clock and the master clock.
  • Improving Electro-Magnetic Noise Immunity in Serial Communications Systems (Rev. A)
    PDF, 60 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    This application note provides key recommendations for implementing serial communication systems that exceed IEC immunity test standards. To provide an example of highly reliable serial communications system implementation and testing, a Texas Instruments DP83640 Ethernet Physical Layer device was tested for International Electrotechnical Commission (IEC) immunity test compliance. Results from the
  • AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output (Rev. D)
    PDF, 209 Kb, 修订版: D, 档案已发布: Apr 26, 2013
    The DP83640 provides a highly precise, low-jitter clock output that is frequency-aligned to the masterIEEE 1588 clock and can be phase-aligned as well. Empirical testing shows very low jitter (less than 1 nspeak-to-peak and standard deviation when using the FCO source) and precise phase alignment. Whiletest results show that the FCO has superior long term jitter performance, using the PGM as
  • DP83640 Synchronous Ethernet Mode: Achieving Sub-ns Accuracy in PTP Applications (Rev. A)
    PDF, 757 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    This application note first provides a summary of empirical results found when master to slave node synchronization is measured with Synchronous Ethernet mode enabled. Background information is then provided describing the operation of and topological constraints associated with Synchronous Ethernet mode. Typical applications are then described, followed by empirical data which clearly demonstrate
  • AN-2006 Synchronizing a DP83640 PTP Master to a GPS Receiver (Rev. A)
    PDF, 35 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    This application report discusses methods of synchronizing the precision time protocol (PTP) clock to aGPS receiver using the DP83640 precision PHYTERв„ў.
  • Reducing Radiated Emissions in Ethernet 10/100 LAN Applications (Rev. A)
    PDF, 70 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    This application report explains how Texas Instruments' PHYTER products help system designers toreduce radiated emissions in Ethernet 10/100 LAN applications.
  • IEEE 1588 Synchronization Over Standard Networks Using the DP83640 (Rev. A)
    PDF, 87 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    This application report describes a method of synchronization that provides much more accuratesynchronization in systems with larger PDV. The method described attempts to detect minimum delays, or'lucky packets'. The method also takes advantage of the DP83640 clock control mechanism to separatelycontrol clock rate and time corrections, minimizing overshoot or wild swings in the accuracy of t
  • IEEE 1588 Boundary Clock and Transparent Clock Implementation Using the DP83640 (Rev. A)
    PDF, 98 Kb, 修订版: A, 档案已发布: Apr 26, 2013
    TIs DP83640 precision PHYTERв„ў implements time-critical portions of the IEEE 1588 Precision TimeProtocol (PTP), allowing high precision IEEE 1588 node implementations. These same features can beused to implement multi-port boundary clock (BC) and transparent clock (TC) devices as well.
  • AN-1540 Power Measurement of Ethernet Physical Layer Products (Rev. B)
    PDF, 79 Kb, 修订版: B, 档案已发布: Apr 26, 2013
    System designers require accurate component power consumption specifications, for the purposes of thermal management, component selection, and power distribution planning.
  • AN-1548 PHYTER 100 Base-TX Reference Clock Jitter Tolerance (Rev. B)
    PDF, 126 Kb, 修订版: B, 档案已发布: Apr 26, 2013
    The use of a reference clock that is less stable than those directly driven from an oscillator may be required for some applications. In addition, some customer applications may require partnering with devices that operate outside of the IEEE 802.3 standard for transmitted jitter.

模型线

制造商分类

  • Semiconductors> Interface> Ethernet