Datasheet Texas Instruments LMP7721 — 数据表
制造商 | Texas Instruments |
系列 | LMP7721 |
3飞安输入偏置电流精密放大器
数据表
LMP7721 3-Femtoampere Input Bias Current Precision Amplifier datasheet
PDF, 1.0 Mb, 修订版: E, 档案已发布: Dec 15, 2014
从文件中提取
价格
状态
LMP7721MA/NOPB | LMP7721MAX/NOPB | |
---|---|---|
Lifecycle Status | Active (Recommended for new designs) | Active (Recommended for new designs) |
Manufacture's Sample Availability | No | Yes |
打包
LMP7721MA/NOPB | LMP7721MAX/NOPB | |
---|---|---|
N | 1 | 2 |
Pin | 8 | 8 |
Package Type | D | D |
Industry STD Term | SOIC | SOIC |
JEDEC Code | R-PDSO-G | R-PDSO-G |
Package QTY | 95 | 2500 |
Carrier | TUBE | LARGE T&R |
Device Marking | LMP77 | 21MA |
Width (mm) | 3.91 | 3.91 |
Length (mm) | 4.9 | 4.9 |
Thickness (mm) | 1.58 | 1.58 |
Pitch (mm) | 1.27 | 1.27 |
Max Height (mm) | 1.75 | 1.75 |
Mechanical Data | 下载 | 下载 |
参数化
Parameters / Models | LMP7721MA/NOPB | LMP7721MAX/NOPB |
---|---|---|
Additional Features | N/A | N/A |
Architecture | CMOS | CMOS |
CMRR(Min), dB | 84 | 84 |
CMRR(Typ), dB | 100 | 100 |
GBW(Typ), MHz | 17 | 17 |
Input Bias Current(Max), pA | 0.02 | 0.02 |
Iq per channel(Max), mA | 1.7 | 1.7 |
Iq per channel(Typ), mA | 1.3 | 1.3 |
Number of Channels | 1 | 1 |
Offset Drift(Typ), uV/C | 1.5 | 1.5 |
Operating Temperature Range, C | -40 to 125 | -40 to 125 |
Output Current(Typ), mA | 22 | 22 |
Package Group | SOIC | SOIC |
Package Size: mm2:W x L, PKG | 8SOIC: 29 mm2: 6 x 4.9(SOIC) | 8SOIC: 29 mm2: 6 x 4.9(SOIC) |
Rail-to-Rail | In to V-,Out | In to V-,Out |
Rating | Catalog | Catalog |
Slew Rate(Typ), V/us | 10.5 | 10.5 |
Total Supply Voltage(Max), +5V=5, +/-5V=10 | 5.5 | 5.5 |
Total Supply Voltage(Min), +5V=5, +/-5V=10 | 1.8 | 1.8 |
Vn at 1kHz(Typ), nV/rtHz | 6.5 | 6.5 |
Vos (Offset Voltage @ 25C)(Max), mV | 0.15 | 0.15 |
生态计划
LMP7721MA/NOPB | LMP7721MAX/NOPB | |
---|---|---|
RoHS | Compliant | Compliant |
应用须知
- AN-1798 Designing with Electro-Chemical Sensors (Rev. C)PDF, 62 Kb, 修订版: C, 档案已发布: May 1, 2013
As early as 1950, electro-chemical sensors were used for oxygen (gas) monitoring; however, with increasing concerns about personal safety, the demand for portable electro-chemical sensors has dramatically increased. Today, electro-chemical sensors are commonly used in portable equipment todetect different toxic gases. - AN-1852 Designing With pH Electrodes (Rev. A)PDF, 115 Kb, 修订版: A, 档案已发布: May 1, 2013
A pH electrode measures hydrogen ion (H+) activity and produces an electrical potential or voltage. Theoperation of the pH electrode is based on the principle that an electric potential develops when two liquidsof different pH come into contact at opposite sides of a thin glass membrane. This was originallydiscovered in 1906 by Max Cremer [1]. His discovery laid the foundation for Fritz Habe
模型线
系列: LMP7721 (2)
制造商分类
- Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Precision Op Amps