Datasheet Texas Instruments MSP430FR69271 — 数据表
制造商 | Texas Instruments |
系列 | MSP430FR69271 |
MSP430FR69271 16 MHz ULP微处理器,具有64 KB FRAM,2 KB SRAM,52 IO,ADC12,LCD,AES
数据表
MSP430FR697x(1), MSP430FR692x(1) Mixed-Signal Microcontrollers datasheet
PDF, 2.4 Mb, 修订版: B, 档案已发布: Mar 9, 2017
从文件中提取
价格
状态
MSP430FR69271IPM | MSP430FR69271IPMR | MSP430FR69271IRGCR | MSP430FR69271IRGCT | |
---|---|---|---|---|
Lifecycle Status | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) |
Manufacture's Sample Availability | No | No | No | No |
打包
MSP430FR69271IPM | MSP430FR69271IPMR | MSP430FR69271IRGCR | MSP430FR69271IRGCT | |
---|---|---|---|---|
N | 1 | 2 | 3 | 4 |
Pin | 64 | 64 | 64 | 64 |
Package Type | PM | PM | RGC | RGC |
Industry STD Term | LQFP | LQFP | VQFN | VQFN |
JEDEC Code | S-PQFP-G | S-PQFP-G | S-PQFP-N | S-PQFP-N |
Package QTY | 160 | 1000 | 2000 | 250 |
Device Marking | FR69271 | FR69271 | FR69271 | FR69271 |
Width (mm) | 10 | 10 | 9 | 9 |
Length (mm) | 10 | 10 | 9 | 9 |
Thickness (mm) | 1.4 | 1.4 | .88 | .88 |
Pitch (mm) | .5 | .5 | .5 | .5 |
Max Height (mm) | 1.6 | 1.6 | 1 | 1 |
Mechanical Data | 下载 | 下载 | 下载 | 下载 |
Carrier | LARGE T&R | LARGE T&R | SMALL T&R |
生态计划
MSP430FR69271IPM | MSP430FR69271IPMR | MSP430FR69271IRGCR | MSP430FR69271IRGCT | |
---|---|---|---|---|
RoHS | Compliant | Compliant | Compliant | Compliant |
应用须知
- LC Sensor Rotation Detection With MSP430 Extended Scan Interface (ESI)PDF, 2.2 Mb, 档案已发布: Aug 28, 2014
This application report describes the implementation of a flow meter using the Texas Instruments MSP430FR6989 microcontroller with the Extended Scan Interface (ESI) module. This module can provide a contactless sensing approach to detecting a rotating disc. The number of rotations of the disc indicates the volume flow of gas or water and can be used to calculate the fee for the user. This applicat - Adjustment of ESIOSC Oscillator Frequency (Rev. A)PDF, 192 Kb, 修订版: A, 档案已发布: Jan 30, 2015
The MSP430FR698x Extended Scan Interface (ESI) uses two clock sources. These clocks are ACLK and a high-frequency clock generated by the ESI oscillator, ESIOSC. ESIOSC is realized as an RC-oscillator and shows a temperature and voltage dependency. However, a hardware-supported measurement of ESIOSC frequency and adjustment by software allows compensating for the frequency drift. This application r - Migrating From MSP430FW42x Scan Interface to MSP430FR6x8x/FR5x8x ESI (Rev. A)PDF, 95 Kb, 修订版: A, 档案已发布: Feb 6, 2015
The purpose of this application report is to facilitate the migration of designs based on the MSP430FW42x Scan Interface (SIF) to the MSP430FR5xx/FR6xx Extended Scan Interface (ESI). This document describes the main differences between the two peripheral modules and provides migration solutions covering both software and hardware aspects. - Secure In-Field Firmware Updates for MSP MCUsPDF, 223 Kb, 档案已发布: Nov 17, 2015
In-field firmware update is a feature that is increasingly used in microcontroller-based applications today and important benefits include service and support to products that are already deployed in the field (for example, being able to correct bugs or add new functionalities). As common as in-field firmware updates are in embedded systems, this feature is also commonly exploited by attackers; if - Getting Started With EEMBC ULPBench on MSP-EXP430FR5969 (Rev. A)