Datasheet Texas Instruments OPA454 — 数据表

制造商Texas Instruments
系列OPA454
Datasheet Texas Instruments OPA454

高压(100V),大电流(50mA)运算放大器,G = 1稳定

数据表

OPA454 High-Voltage (100-V), High-Current (50-mA) Operational Amplifiers, G = 1 Stable datasheet
PDF, 1.7 Mb, 修订版: B, 档案已发布: Mar 31, 2016
从文件中提取

价格

状态

OPA454AIDDAOPA454AIDDAG4OPA454AIDDAROPA454AIDDARG4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityYesNoNoYes

打包

OPA454AIDDAOPA454AIDDAG4OPA454AIDDAROPA454AIDDARG4
N1234
Pin8888
Package TypeDDADDADDADDA
Industry STD TermHSOICHSOICHSOICHSOIC
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-G
Package QTY757525002500
CarrierTUBETUBELARGE T&RLARGE T&R
Device MarkingOPA454OPA454OPA454OPA454
Width (mm)3.93.93.93.9
Length (mm)4.894.894.894.89
Thickness (mm)1.481.481.481.48
Pitch (mm)1.271.271.271.27
Max Height (mm)1.71.71.71.7
Mechanical Data下载下载下载下载

参数化

Parameters / ModelsOPA454AIDDA
OPA454AIDDA
OPA454AIDDAG4
OPA454AIDDAG4
OPA454AIDDAR
OPA454AIDDAR
OPA454AIDDARG4
OPA454AIDDARG4
Additional FeaturesShutdownShutdownShutdownShutdown
ArchitectureFETFETFETFET
CMRR(Min), dB100100100100
CMRR(Typ), dB146146146146
GBW(Typ), MHz2.52.52.52.5
Input Bias Current(Max), pA100100100100
Iq per channel(Max), mA4444
Iq per channel(Typ), mA3.23.23.23.2
Number of Channels1111
Offset Drift(Typ), uV/C1.61.61.61.6
Operating Temperature Range, C-55 to 125-55 to 125-55 to 125-55 to 125
Output Current(Typ), mA120120120120
Package GroupSO PowerPADSO PowerPADSO PowerPADSO PowerPAD
Package Size: mm2:W x L, PKG8SO PowerPAD: 29 mm2: 6 x 4.9(SO PowerPAD)8SO PowerPAD: 29 mm2: 6 x 4.9(SO PowerPAD)8SO PowerPAD: 29 mm2: 6 x 4.9(SO PowerPAD)8SO PowerPAD: 29 mm2: 6 x 4.9(SO PowerPAD)
Rail-to-RailNoNoNoNo
RatingCatalogCatalogCatalogCatalog
Slew Rate(Typ), V/us13131313
Total Supply Voltage(Max), +5V=5, +/-5V=10100100100100
Total Supply Voltage(Min), +5V=5, +/-5V=1010101010
Vos (Offset Voltage @ 25C)(Max), mV4444

生态计划

OPA454AIDDAOPA454AIDDAG4OPA454AIDDAROPA454AIDDARG4
RoHSCompliantCompliantCompliantCompliant

应用须知

  • Power Amplifier Stress and Power Handling Limitations
    PDF, 55 Kb, 档案已发布: Sep 27, 2000
    To achieve reliable power amplifier designs you must consider the stress on the amplifier compared to its power handling limitations. Power handling limits are specified by the Safe Operating Area (SOA) curves of the power amp. Stress on the amplifier depends on amplifier load and signal conditions which can be evaluated with straightforward techniques.

模型线

制造商分类

  • Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Power Op Amps