Datasheet Texas Instruments TDC7200PW — 数据表

制造商Texas Instruments
系列TDC7200
零件号TDC7200PW
Datasheet Texas Instruments TDC7200PW

用于LIDAR,磁致伸缩和流量计14-TSSOP -40至85的飞行时间应用的时间数字转换器

数据表

TDC7200 Time-to-Digital Converter for Time-of-Flight Applications in LIDAR, Magnetostrictive and Flow Meters datasheet
PDF, 1.5 Mb, 修订版: D, 档案已发布: Mar 7, 2016
从文件中提取

价格

状态

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

打包

Pin14
Package TypePW
Industry STD TermTSSOP
JEDEC CodeR-PDSO-G
Package QTY90
CarrierTUBE
Device MarkingT7200
Width (mm)4.4
Length (mm)5
Thickness (mm)1
Pitch (mm).65
Max Height (mm)1.2
Mechanical Data下载

参数化

# Input Channels1
Active Supply Current(Typ)1.35 mA
InterfaceSPI
Operating Temperature Range-40 to 85 C
Package GroupTSSOP
Package Size: mm2:W x L14TSSOP: 32 mm2: 6.4 x 5(TSSOP) PKG
RatingCatalog
Sleep Supply Current(Typ)0.3 uA
Special FeaturesTime of flight

生态计划

RoHSCompliant

设计套件和评估模块

  • Evaluation Modules & Boards: TDC1000-TDC7200EVM
    Ultrasonic Sensing Water Flow/Level/Concentration Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: TDC7200EVM
    TDC7200 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: TDC1000-GASEVM
    Ultrasonic Sensing Gas Flow Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

应用须知

  • Interleaved Short Time Measurements Using TDC7200
    PDF, 1.1 Mb, 档案已发布: Oct 30, 2015
    Time-to-digital converters are used in measuring time-of-flight in multiple end applications such as drones, range finders, machine vision, robots, etc. These end applications can either use light waves, ultrasonic waves or other technologies such as RADAR. However, in each of these cases, time-of-flight between the transmitted wave and the reflected wave provides us with dista
  • How to Select and Mount Transducers in Ultrasonic Sensing for Level Sensing and (Rev. A)
    PDF, 1.3 Mb, 修订版: A, 档案已发布: Nov 25, 2015
    Ultrasonic sensing utilizing Time Of Flight (TOF) measurement techniques are used in liquid level and fluid identification sensing in the automotive, consumer and medical markets. Ultrasonic (TOF) sensing can yield high accuracy and high reliability with low-power consumption for all of these markets. In order to achieve the best cost-to-performance combination, care must be ta
  • Measuring an RTD Sensor with the TDC1000 and TDC7200 for Ultrasonic Sensing
    PDF, 107 Kb, 档案已发布: Apr 9, 2015
    This application note describes the firmware procedure for measuring temperature via two RTD's using the TDC1000 and TDC7200. Temperature is monitored in heat meters and flow meters.
  • Ultrasonic Sensing for Fluid Identification and Contamination
    PDF, 153 Kb, 档案已发布: Apr 30, 2015
    Ultrasonic sensing utilizing Time Of Flight (TOF) measurement techniques can be used to monitor material purity/contamination levels and or to differentiate materials non-invasively. This technology has been utilized in the automotive, consumer, medical and food preparation markets worldwide. Ultrasonic (TOF) sensing can yield high accuracy with low power consumption for all of
  • Using Ultrasonic Sensing to Monitor Level in Tanks
    PDF, 5.3 Mb, 档案已发布: Jul 25, 2015
    Ultrasonic sensing Time Of Flight (TOF) measurement techniques can be utilized to measure fluid levels in tanks. Those measurements can either be done from inside or outside the wall of the tank. In automotive, industrial and even medical applications the ability to perform non-invasive measurements is driven from the target fluid's corrosiveness and/or sterile requirements. Th
  • Ultrasonic Sensing Basics for Liquid Level Sensing, Flow Sensing, and Fluid Iden (Rev. A)
    PDF, 276 Kb, 修订版: A, 档案已发布: Jun 11, 2015
    Ultrasonic Sensing Basics for Liquid Level Sensing, Flow Sensing, and Fluid Identification
  • Ultrasonic Sensing for Water Flow Meters and Heat Meters
    PDF, 662 Kb, 档案已发布: Apr 30, 2015
    Ultrasonic flow meters are gaining wide usage in commercial, industrial and medical applications. Major benefits of utilizing this type of flowmeter are higher accuracy, low maintenance (no moving parts), non-invasive flow measurement, and the ability to regularly diagnose health of the meter. This application note is intended as an introduction to ultrasonic time-of-flight (TO
  • Design of Analog Interface for Ultrasonic Gas Flow Meter Sensors (Rev. A)
    PDF, 2.0 Mb, 修订版: A, 档案已发布: Mar 27, 2016
    Transit-time ultrasonic gas flow meters have gained acceptance in applications for gas transferdistribution. Advantages of this technology include: wide measuring range, relatively high accuracy, goodrepeatability, negligible pressure drop, general insensitivity to liquid contaminants, insensitivity tofluctuations of the gas composition, and low maintenance.This application note covers t

模型线

系列: TDC7200 (2)

制造商分类

  • Semiconductors > Sensing Products > Ultrasonic Sensing