Datasheet Linear Technology LTC1967 — 数据表

制造商Linear Technology
系列LTC1967

精密扩展带宽,RMS-DC转换器

数据表

LTC1967 - Precision Extended Bandwidth, RMS-to-DC Converter
PDF, 336 Kb, 文件上传: Aug 15, 2017
从文件中提取

价格

打包

LTC1967CMS8#PBFLTC1967CMS8#TRPBFLTC1967IMS8#PBFLTC1967IMS8#TRPBF
N1234
PackageMS-8
包装外形图
MS-8
包装外形图
MS-8
包装外形图
MS-8
包装外形图
Package CodeMS8MS8MS8MS8
Package Index05-08-166005-08-166005-08-166005-08-1660
Pin Count8888

参数化

Parameters / ModelsLTC1967CMS8#PBFLTC1967CMS8#TRPBFLTC1967IMS8#PBFLTC1967IMS8#TRPBF
1% Error Bandwidth, kHz40404040
3dB Error Bandwidth, kHz4000400040004000
Conversion Gain Error, %0.10.10.10.1
Demo BoardsDC427B-BDC427B-BDC427B-BDC427B-B
Design ToolsLTspice ModelLTspice ModelLTspice ModelLTspice Model
Export Controlnononono
Isupply, mA0.320.320.320.32
Linearity Error, %0.020.020.020.02
Operating Temperature Range, °C0 to 700 to 70-40 to 85-40 to 85
Vin Max, V1.051.051.051.05
Vs Max, V6666
Vs Min, V4.54.54.54.5

生态计划

LTC1967CMS8#PBFLTC1967CMS8#TRPBFLTC1967IMS8#PBFLTC1967IMS8#TRPBF
RoHSCompliantCompliantCompliantCompliant

应用须知

  • Instrumentation Circuitry Using RMS-to-DC Converters &mdash AN106
    PDF, 354 Kb, 档案已发布: Feb 21, 2007
    It is widely acknowledged that RMS measurement of waveforms furnishes the most accurate amplitude information. Rectify-andaverage schemes, usually calibrated to a sine wave, are only accurate for one waveshape. Departures from this waveshape result in pronounced errors. Although accurate, RMS conversion often entails limited bandwidth, restricted range, complexity and difficult to characterize dynamic and static errors. The LTC1966/67/68 RMS converter family addresses these issues, making instrument grade applications practical. A variety of instrumentation oriented applications are presented. Included are basic circuits, a fully isolated AC line monitor, a distortionless AC line voltage regulator, wideband X1000 pre-amplifiers, a quartz crystal RMS current meter, a crystal stabilized AC voltage reference, an RMS amplitude leveled random noise generator and an RMS amplitude level controller. Appended sections cover RMS theory and converter operation, AC measurement and signal handling practice, test equipment recommendations, noise theory and noise diodes.
    从文件中提取

设计须知

  • Precision LVDT Signal Conditioning Using Direct RMS to DC Conversion &mdash DN362
    PDF, 75 Kb, 档案已发布: Mar 23, 2005
    从文件中提取

文章

  • Accurate and Simple AC Measurement to 500kHz &mdash LT Journal
    PDF, 166 Kb, 档案已发布: Mar 25, 2005
    从文件中提取

模型线

制造商分类

  • Signal Conditioning > RMS-DC Conversion