Datasheet Texas Instruments ADS122U04IPWR — 数据表
制造商 | Texas Instruments |
系列 | ADS122U04 |
零件号 | ADS122U04IPWR |
具有PGA,Vref,2x IDAC和UART接口的24位2kSPS,4通道,低功耗Δ-ΣADC 16-TSSOP -40至125
数据表
ADS122U04 24-Bit, 4-Channel, 2-kSPS, Delta-Sigma ADC With UART Interface datasheet
PDF, 2.1 Mb, 修订版: A, 档案已发布: Aug 16, 2017
从文件中提取
价格
状态
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes |
打包
Pin | 16 |
Package Type | PW |
Industry STD Term | TSSOP |
JEDEC Code | R-PDSO-G |
Package QTY | 2000 |
Carrier | LARGE T&R |
Device Marking | ADS122U |
Width (mm) | 4.4 |
Length (mm) | 5 |
Thickness (mm) | 1 |
Pitch (mm) | 0.65 |
Max Height (mm) | 1.2 |
Mechanical Data | 下载 |
参数化
Analog Voltage AVDD(Max) | 5.5 V |
Analog Voltage AVDD(Min) | 2.3 V |
Architecture | Delta-Sigma |
Digital Supply(Max) | 5.5 V |
Digital Supply(Min) | 2.3 V |
Features | 50/60 Hz Rejection,Excitation Current Sources (iDACs),GPIO,Oscillator,PGA,Temp Sensor,Small Size |
Input Range(Max) | 2.85,5.6 V |
Input Range(Min) | -2.85,0 V |
Input Type | Differential,Single-Ended |
Interface | UART |
Multi-Channel Configuration | Multiplexed |
Number of input channels | 4 |
Operating Temperature Range | -40 to 125 C |
Package Group | TSSOP|16,WQFN|16 |
Package Size: mm2:W x L | 16TSSOP: 22 mm2: 4.4 x 5 (TSSOP|16),16WQFN: 9 mm2: 3 x 3 (WQFN|16) PKG |
Power Consumption(Typ) | 1.4 mW |
Rating | Catalog |
Reference Mode | Ext,Int |
Resolution | 24 Bits |
Sample Rate(Max) | 2 MSPS |
生态计划
RoHS | Compliant |
设计套件和评估模块
- Evaluation Modules & Boards: ADS122U04EVM
ADS122U04 Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
应用须知
- Low-Cost Single-Chip Diff Temp Measurement Solution Using Delta-Sigma ADCs (Rev. A)PDF, 486 Kb, 修订版: A, 档案已发布: May 4, 2018
- Reducing System Cost Size and Power in Isolated DAQ Systems Using ADS122U04 (Rev. A)PDF, 763 Kb, 修订版: A, 档案已发布: Jun 15, 2017
- A Basic Guide to Thermocouple MeasurementsPDF, 298 Kb, 档案已发布: Sep 28, 2018
Thermocouples are common temperature sensors used in a wide variety of commercial and industrialapplications. While slightly less accurate than resistance temperature detectors (RTDs) thermocouplescover a wide temperature range are self-powered and have a fast response time. Their simpleconstruction make them inexpensive and durable. Because of the small sensor voltage and low noiserequ - A Basic Guide to RTD MeasurementsPDF, 333 Kb, 档案已发布: Jun 19, 2018
RTDs or resistance temperature detectors are sensors used to measure temperature. These sensors arethe among the most accurate temperature sensors available covering large temperature ranges.However getting accurate measurements with precision analog-to-digital converters (ADCs) requiresattention to detail in design of measurement circuits and calculation of the measurement. This applica - Digital Filter Types in Delta-Sigma ADCsPDF, 219 Kb, 档案已发布: Jun 27, 2017
This application report discusses digital filters which are a ubiquitous feature in delta-sigma analog todigital converters (ADCs). Digital low-pass filters are essential to the functionality of a delta-sigma ADCwhich relies on oversampling and noise shaping to push quantization noise out of band. There arevariations between the types of digital filters used in delta-sigma ADCs that provide
模型线
系列: ADS122U04 (4)
- ADS122U04IPW ADS122U04IPWR ADS122U04IRTER ADS122U04IRTET
制造商分类