P OWE R T RAN S FO R M E R
CHASSIS MOUNT : Isolation N-48X
Electrical Specifications (@25°C)
1. Maximum Power:
15 VA
2. Input Voltage:
115 V, 50 / 60 Hz
3. Output Voltage:
115V + 5%
4. Full Secondary Load: 0.13 Amps RMS
5. Voltage Regulation: 20 % TYP @ full load to no load Description:
The N-48X is a power transformer for isolating equipment from direct connection to
the powerline. The primary and secondary coils are concentrically wound providing
excellent magnetic coupling. Having good magnetic coupling between windings
helps reduce leakage flux and phase shift.
A Safety: Dimensions: Unit: In inches A B C D 1.937 3.312 2.00 2.812 BLK WHT BLK These units are designed with 1500V isolation between winding to winding and
between winding and core. Materials and construction are rated for Class B
insulation system. B
D Weight: 1.35 lbs
Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin C RED BLK RED 2 HOLES BLK .187 DIA (REF) Schematic: Input: Blk to Blk
Output: Red to Red
Shield: Wht
RoHS Compliance: As of manufacturing date February 2016, all standard products meet …