Datasheet Texas Instruments INA101CM — 数据表

制造商Texas Instruments
系列INA101
零件号INA101CM
Datasheet Texas Instruments INA101CM

超高精度仪表放大器10-TO-100

数据表

Very High Accuracy Instrumentation Amplifier datasheet
PDF, 262 Kb, 档案已发布: Sep 27, 2000
从文件中提取

价格

状态

Lifecycle StatusNRND (Not recommended for new designs)
Manufacture's Sample AvailabilityNo

打包

Pin10
Package TypeLME
Industry STD TermTO-CAN
JEDEC CodeO-MBCY-W
Package QTY20
CarrierTUBE
Device MarkingINA101CM
Width (mm)8.96
Length (mm)8.96
Thickness (mm)4.4
Pitch (mm)2.92
Max Height (mm)5.72
Mechanical Data下载

参数化

Bandwidth at Min Gain(Typ)0.3 MHz
CMRR(Min)106 dB
Gain Error (+/-)(Max)0.2 %
Gain Non-Linearity (+/-)(Max)0.002 %
Gain(Max)1000 V/V
Gain(Min)1 V/V
Input Bias Current (+/-)(Max)30 nA
Input Offset (+/-)(Max)50 uV
Input Offset Drift (+/-)(Max)2 uV/C
Iq(Typ)6.7 mA
Noise at 0.1 Hz - 10 Hz(Typ)0.8 uVpp
Noise at 1kHz(Typ)(nV/rt13 Hz
Number of Channels1
Operating Temperature Range-55 to 125 C
Package GroupPDIP,SOIC
Package Size: mm2:W x LSee datasheet (PDIP),16SOIC: 106 mm2: 10.3 x 10.3(SOIC) PKG
RatingCatalog
Vs(Max)40 V
Vs(Min)10 V

生态计划

RoHSCompliant

应用须知

  • AC Coupling Instrumentation and Difference Amplifiers
    PDF, 38 Kb, 档案已发布: Sep 27, 2000
    The need to glean AC signals from DC in the presence of common-mode noise frequently occurs in signal conditioning applications. AC coupling to an instrumentation amplifier (IA) or difference amplifier can be used to accurately extract the AC signal while rejecting DC and common-mode noise.

模型线

制造商分类

  • Semiconductors > Amplifiers > Instrumentation Amplifiers