TL601, TL604, TL607, TL610P-MOS ANALOG SWITCHES D2161, JUNE 1976 — REVISED OCTOBER 1986 absolute maximum ratings over operating free-air temperature range (unless otherwise noted) Supply voltage, VCC+ (see Note 1) . 30 V Supply voltage, VCC– . –30 V VCC+ to VCC– supply voltage differential . 35 V Control input voltage . VCC+ Switch off-state voltage . 30 V Switch on-state current . 10 mA Operating free-air temperature range: TL601C, TL604C, TL607C, TL610C . 0°C to 70°C TL601I, TL604I, TL607I, TL610I . – 25°C to 85°C TL601M, TL604M, TL607M, TL610M . – 55°C to 125°C Storage temperature range . – 65°C to 150°C Lead temperature (1,6 mm) 1/16 inch from case for 60 seconds: JG package . 300°C Lead temperature (1,6 mm) 1/16 inch from case for 10 seconds: P package . 260°C NOTE 1: All voltage values are with respect to network ground terminal. recommended operating conditionsTL601C, TL604CTL601I, TL604ITL601M, TL604MTL607C, TL610CTL607I, TL610ITL607M, TL610MUNITMINTYPMAXMINTYPMAXMINTYPMAX Supply voltage, VCC+ (see Figure 1) 5 10 25 5 10 25 5 10 25 V Supply voltage, VCC– (see Figure 1) – 5 – 20 – 25 – 5 – 20 – 25 – 5 – 20 – 25 V VCC+ to VCC– supply voltage differential 15 30 15 30 15 30 V (see Figure 1) High-level control input voltage, VIH 2 5.5 2 5.5 2 5.5 V Low-level control input voltage, VIL All inputs 0.8 0.8 0.8 Voltage at any analog switch (S) terminal VCC– + 8 VCC+ VCC– + 8 VCC+ VCC– + 8 VCC+ V Switch on-state current 10 10 10 mA Operating free-air temperature, TA 0 70 25 85 –55 125 °C POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3