TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions 2/ Temperature, Device Limits Unit T type A Min Max Gain - continued. Gain nonlinearity G = 1 to 10, RL = 10 k, 25C 01 15 ppm VOUT = -10 V to +10 V 5 typical G = 100, RL = 10 k, 20 VOUT = -10 V to +10 V 7 typical G = 1000, RL = 10 k, 50 VOUT = -10 V to +10 V 10 typical G = 1 to 100, RL = 2 k, 100 VOUT = -10 V to +10 V 15 typical Gain versus G = 1 25C 01 10 ppm/C temperature 3 typical G 1 3/ -50 Input Differential input 5/ 25C 01 100||2 typical G||pF impedance Common mode input 5/ 25C 01 100||2 typical G||pF impedance Input operating 6/ V V S = 2.3 V to 5 V 25C 01 -VS +VS voltage range + 1.9 – 1.1 -55C to +125C -V S +VS + 2.0 – 1.2 Input operating voltage V V S = 5 V to 18 V 25C 01 -VS +VS range + 1.9 – 1.2 -55C to +125C -V S +VS + 2.0 – 1.3 See footnotes at end of table. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/16619 REV PAGE 8