Datasheet HMC602LP4, 602LP4E (Analog Devices)

制造商Analog Devices
描述70 dB, Logarithmic Detector/Controller SMT, 1 - 8000 MHz
页数 / 页10 / 1 — HMC602LP4 / 602LP4E. 70 dB, LOGARITHMIC. DETECTOR / CONTROLLER, 1 - 8000 …
文件格式/大小PDF / 598 Kb
文件语言英语

HMC602LP4 / 602LP4E. 70 dB, LOGARITHMIC. DETECTOR / CONTROLLER, 1 - 8000 MHz. Typical Applications. Features. Functional Diagram

Datasheet HMC602LP4, 602LP4E Analog Devices

文件文字版本

HMC602LP4 / 602LP4E
v03.0209
70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz Typical Applications Features
The HMC602LP4(E) is ideal for IF and RF applica- Wide Dynamic Range: up to 70 dB tions in: High Accuracy: ±1 dB with 60 dB Range Up To 6 GHz • Cellular/PCS/3G Fast: 10ns Output Response Time • WiMAX, WiBro, WLAN, Fixed Wireless & Radar Supply Voltage: +5V • Power Monitoring & Control Circuitry Power-Down Mode Excellent Stability over Temperature • Receiver Signal Strength Indication (RSSI) Buffered Temperature Sensor Output • Automatic Gain & Power Control Compact 4x4mm Leadless SMT Package 12
Functional Diagram General Description
The HMC602LP4(E) Logarithmic Detector/Controller converts RF signals at its input, to a proportional DC T voltage at its output. The HMC602LP4(E) employs a successive compression topology which delivers extremely high dynamic range and conversion accuracy over a wide input frequency range. As the input power is increased, successive amplifi ers move into saturation S - SM one by one creating an accurate approximation of the R logarithm function. The output of a series of square law O detectors is summed, converted into voltage domain T and buffered to drive the LOGOUT output. For detection C mode, the LOGOUT pin is shorted to the VSET input, E and will provide a nominal logarithmic slope of -25mV/ T dB and an intercept of 18 dBm (23 dBm for ƒ > 5.8 GHz). E The HMC602LP4(E) can also be used in the controller mode where an external voltage is applied to the VSET pin, to create an AGC or APC feedback loop. R D E
Electrical Specifi cations, TA = +25C, EN= 5V, Vcc1, Vcc2, Vcc3= +5V [1]
W Parameter Typ. Typ. Typ. Typ. Typ. Typ. Typ. Typ. Typ. Units O Input Frequency 50 100 900 1900 2200 3600 5800 7000 8000 MHz P ±3 dB Dynamic Range 69 70 71 71 71 68 66 61 56 dB ±3 dB Dynamic Range Center -24.5 -25 -25.5 -25.5 -25.5 -24 -23 -20.5 -19 dBm ±1 dB Dynamic Range 61 61 62 62 63 62 63 56 49 dB Output Intercept 18.2 18 18.7 19.8 20.2 23.1 24.4 23 21.6 dBm Output Slope -25.6 -25.5 -25.3 -25 -25 -24.6 -25.4 -27.5 -30 mV/dB Temperature Sensitivity @ -10 dBm Input [2] 16 16 14 14 15 16 15 14 22 mdB/°C [1] Detector mode measurements; LOGOUT (Pin 15) is shorted to VSET (Pin 16). [2] Measured from T = -40C to T A A = +85C [3] C9 removed from production board Parameter Conditions Min. Typ. Max. Units
LOGOUT Interface
Output Voltage Range 0 Vcc -1.0 V Output Fall Time -10 dBm Input Pulsed; Measured from 10% to 90% [3] 9.5 ns Output Rise Time -10 dBm Input Pulsed; Measured from 10% to 70% [3] 10 ns
VSET Interface
Input Impedance 30 kΩ Input Voltage Range 0.25 to 2.0 V Low Frequency Gain VSET to LOGOUT 56 dB Information furnis F heod r pri by An ce, de alog Devi lcievs eir s y b , a eliev nd to pla ed to be accu ce o rate anrder d relia sbl, pl e. H ease co owever, no For price, delivery, and to place orders: Analog Devices, Inc., responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other ntact Hittite Microwave Corporation: One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106 20 Alpha Road, Chelmsford, MA 01824 Phone: 978 rights of third parties that may result from its use. Specifications subject to change without notice. No Ph - o 25 ne 0 : 7 -3 81- 3 3 4 29 3 F -470 ax: 978 0 • Orde - r o 25 nlin 0- e a3 t 373
12 - 18
license is granted by implication or otherwise under any patent or patent rights of Analog Devices. www.analog.com Order On-l Trademarks and registered trademarks are the property of their respective owners. ine at www.hit A ti p te.co plicati m on Support: Phone: 1-800-ANALOG-D