1.3 Absolute maximum ratings. 1/ Supply voltage (VPS1/VPS2) .. 7.5 V Enable input (ENBL) .. VPS1/VPS2 Limiter output current (LIMHI, LIMLO) ... 11 mA Minimum VLOG output load resistance ... 40 Ω Power dissipation (PD) .. 800 mW Input level, differential (reference 50 Ω) ... +26 dBm Input level, single ended (reference 50 Ω) .. +20 dBm Storage temperature range .. -65°C to +150°C Junction temperature (TJ): (both packages) .. 150°C Lead temperature (soldering, 10 seconds) .. 300°C Thermal resistance, junction-to-case (θJC) : Case outline E ... 30°C/W Case outline X ... 67°C/W 2/ Thermal resistance, junction-to-ambient (θJA) : Case outline E ... 100°C/W Case outline X ... 85°C/W 3/ 1.4 Recommended operating conditions. Operating voltage range (VPS1/VPS2) .. 2.7 V to 6.5 V Ambient operating temperature range (TA) ... -55°C to +125°C 1.4.1 Operating performance characteristics. (TA = +25°C, VPS = 5 V, unless otherwise specified). Limiter amplifier section (LIMHI, LIMLO): Phase variation at 100 MHz (over input range -73 dBV to -3 dBV) .. ±2° Rise / fall time (10% - 90%, RL = 50 Ω, 40 Ω ≤ RLIM ≤ 400 Ω) .. 0.6 ns Logarithmic amplifier section (VLOG): ± 3 dB error dynamic range (from noise floor to maximum input) .. 100 dB Output voltage (input = -91 dBV at VPS = 2.7 V, 5 V) .. 0.34 V Output voltage (input = +9 dBV at VPS = 5 V) ... 2.34 V Output voltage (input = -3 dBV at VPS = 3 V) .. 2.10 V Output resistance .. 0.3 Ω Maximum output sink current (to ground) .. 1 mA Small signal bandwidth .. 3.5 MHz Input stage section (INHI, INLO): Equivalent power in 50 Ω ( 52.3 Ω in parallel with RIN ) .. +22 dBm Equivalent power in 50 Ω ( 400 MHz bandwidth ) .. -78 dBm Noise floor terminated 50 Ω source ... 1.28 nV / Hz Input capacitance ( from INHI to INLO ) .. 2.5 pF DC bias voltage ( either INHI, INLO ) .. 1.725 V ______ 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Measurement taken under absolute worst case condition and represents data taken with a thermal camera for highest power density location. See MIL-STD-1835 for average package thermal numbers. Contact the manufacturer for improved thermal limits if LIMHI/LIMLO outputs are not used. 3/ Measurement taken under absolute worst case condition. Data taken with a thermal camera for highest power density location. Contact the manufacturer for improved thermal limits if LIMHI/LIMLO outputs are not used. STANDARD SIZE 5962-98646MICROCIRCUIT DRAWINGA DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 D 3 DSCC FORM 2234 APR 97 Document Outline DEPARTMENT OF DEFENSE SPECIFICATION DEPARTMENT OF DEFENSE STANDARDS