Datasheet ADIS16003 (Analog Devices) - 5

制造商Analog Devices
描述Dual-Axis ±1.7 g Accelerometer with SPI Interface
页数 / 页17 / 5 — ADIS16003. Data Sheet. TIMING SPECIFICATIONS. Table 2. Parameter1. , 2. …
修订版B
文件格式/大小PDF / 264 Kb
文件语言英语

ADIS16003. Data Sheet. TIMING SPECIFICATIONS. Table 2. Parameter1. , 2. CC = 3.3 V. VCC = 5 V. Unit. Description

ADIS16003 Data Sheet TIMING SPECIFICATIONS Table 2 Parameter1 , 2 CC = 3.3 V VCC = 5 V Unit Description

该数据表的模型线

文件文字版本

link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 6 link to page 6 link to page 6
ADIS16003 Data Sheet TIMING SPECIFICATIONS
TA = −40°C to +125°C, acceleration = 0 g, unless otherwise noted.
Table 2. Parameter1 , 2 V CC = 3.3 V VCC = 5 V Unit Description
f 3 SCLK 10 10 kHz min 2 2 MHz max tCONVERT 14.5 × tSCLK 14.5 × tSCLK tACQ 1.5 × tSCLK 1.5 × tSCLK Throughput time = tCONVERT + tACQ = 16 tSCLK t1 10 10 ns min TCS/CS to SCLK setup time t 4 2 60 30 ns max Delay from TCS/CS until DOUT three-state disabled t 4 3 100 75 ns max Data access time after SCLK falling edge t4 20 20 ns min Data setup time prior to SCLK rising edge t5 20 20 ns min Data hold time after SCLK rising edge t6 0.4 × tSCLK 0.4 × tSCLK ns min SCLK high pulse width t7 0.4 × tSCLK 0.4 × tSCLK ns min SCLK low pulse width t 5 8 80 80 ns max TCS/CS rising edge to DOUT high impedance t 6 9 5 5 μs typ Power-up time from shutdown 1 Guaranteed by design. All input signals are specified with tr and tf = 5 ns (10% to 90% of VCC) and timed from a voltage level of 1.6 V. The 3.3 V operating range spans from 3.0 V to 3.6 V. The 5 V operating range spans from 4.75 V to 5.25 V. 2 See Figure 3 and Figure 4. 3 Mark/space ratio for the SCLK input is 40/60 to 60/40. 4 Measured with the load circuit in Figure 2 and defined as the time required for the output to cross 0.4 V or 2.0 V with VCC = 3.3 V and time for an output to cross 0.8 V or 2.4 V with VCC = 5.0 V. 5 t8 is derived from the measured time taken by the data outputs to change 0.5 V when loaded with the circuit in Figure 2. The measured number is then extrapolated back to remove the effects of charging or discharging the 50 pF capacitor. This means that the time, t8, quoted in the timing characteristics is the true bus relinquish time of the part and is independent of the bus loading. 6 Shut-down recovery time denotes the time it takes to start producing samples and does not account for the recovery time of the sensor, which is dependent on the overall bandwidth. Rev. B | Page 4 of 16 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS TIMING SPECIFICATIONS CIRCUIT AND TIMING DIAGRAMS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS THEORY OF OPERATION ACCELEROMETER DATA FORMAT SELF-TEST SERIAL INTERFACE ACCELEROMETER SERIAL INTERFACE Accelerometer Control Register Power Down ADD0 ZERO ONE DONTC Accelerometer Conversion Details TEMPERATURE SENSOR SERIAL INTERFACE Read Operation Write Operation Temperature Sensor Control Register ZERO Output Data Format Temperature Sensor Conversion Details POWER SUPPLY DECOUPLING SETTING THE BANDWIDTH SELECTING FILTER CHARACTERISTICS:THE NOISE/BANDWIDTH TRADE-OFF APPLICATIONS INFORMATION DUAL-AXIS TILT SENSOR Converting Acceleration to Tilt SECOND LEVEL ASSEMBLY OUTLINE DIMENSIONS ORDERING GUIDE