ADIS16445Data SheetABSOLUTE MAXIMUM RATINGS Table 3. Stresses at or above those listed under Absolute Maximum Rat- ParameterRating ings may cause permanent damage to the product. This is a Acceleration stress rating only; functional operation of the product at these Any Axis, Unpowered 2000 g or any other conditions above those indicated in the operational Any Axis, Powered 2000 g section of this specification is not implied. Operation beyond VDD to GND −0.3 V to +3.45 V the maximum operating conditions for extended periods may Digital Input Voltage to GND −0.3 V to +VDD + 0.3 V affect product reliability. Digital Output Voltage to GND −0.3 V to +VDD + 0.3 V Table 4. Package Characteristics Temperature θθMass Operating Range −40°C to +105°C JAJCPackage Type(°C/W)(°C/W)(grams) Storage Range −65°C to +125°C1, 2 20-Lead Module (ML-20-3) 36.5 16.9 15 1 Extended exposure to temperatures outside the specified temperature range of −40°C to +105°C can adversely affect the accuracy of the factory calibration. For best accuracy, store the parts within the specified operating range of −40°C to +105°C. ESD CAUTION 2 Although the device is capable of withstanding short-term exposure to 150°C, long-term exposure threatens internal mechanical integrity. Rev. F | Page 6 of 22 Document Outline Features Applications General Description Functional Block Diagram Table of Contents Revision History Specifications Timing Specifications Timing Diagrams Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics User Registers User Interface Reading Sensor Data Burst Read Function SPI Read Test Sequence Device Configuration Dual Memory Structure Output Data Registers Gyroscopes Accelerometers Internal Temperature System Functions Global Commands Product Identification Self-Test Function Status/Error Flags Memory Management Checksum Test Input/Output Configuration Data Ready Indicator General-Purpose Input/Output Example Input/Output Configuration Digital Processing Configuration Gyroscopes/Accelerometers Input Clock Configuration Digital Filtering Dynamic Range Calibration Gyroscopes Gyroscope Bias Error Estimation Gyroscope Bias Correction Factors Single Command Bias Correction Accelerometers Accelerometer Bias Error Estimation Accelerometer Bias Correction Factors Point of Percussion Alignment Flash Updates Restoring Factory Calibration Alarms Static Alarm Use Dynamic Alarm Use Alarm Reporting Alarm Example Applications Information Mounting Tips Power Supply Considerations ADIS16445/PCBZ Installation PC-Based Evaluation Tools Outline Dimensions Ordering Guide