ADXRS646Data SheetABSOLUTE MAXIMUM RATINGS Table 2. Drops onto hard surfaces can cause shocks of greater than 10,000 g and can exceed the absolute maximum rating of the Parameter Rating device. Care should be exercised in handling to avoid damage. Acceleration (Any Axis, 0.5 ms) Unpowered 10,000 g RATE SENSITIVE AXIS Powered 10,000 g This is a Z-axis rate-sensing device (also called a yaw rate- VDD, AVCC −0.3 V to +6.6 V sensing device). It produces a positive going output voltage VRATIO AVCC for clockwise rotation about the axis normal to the package ST1, ST2 AVCC top, that is, clockwise when looking down at the package lid. Output Short-Circuit Duration Indefinite (Any Pin to Common) Operating Temperature Range −55°C to +125°C RATERATE OUTAXIS Storage Temperature Range −65°C to +150°C AVCC = 5VLONGITUDINAL4.75V+ Stresses at or above those listed under Absolute Maximum Ratings AXIS7VRATIO/2 may cause permanent damage to the product. This is a stress RATE IN rating only; functional operation of the product at these or any 1A1A B C D E F G0.25V other conditions above those indicated in the operational section of 002 1- GND this specification is not implied. Operation beyond the maximum LATERAL AXIS 977 0 operating conditions for extended periods may affect product Figure 2. RATEOUT Signal Increases with Clockwise Rotation reliability. ESD CAUTION Rev. C | Page 4 of 12 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS RATE SENSITIVE AXIS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS THEORY OF OPERATION SETTING BANDWIDTH TEMPERATURE OUTPUT AND CALIBRATION SUPPLY RATIOMETRICITY NULL ADJUSTMENT SELF-TEST FUNCTION CONTINUOUS SELF-TEST MODIFYING THE MEASUREMENT RANGE IMMUNITY TO VIBRATION OUTLINE DIMENSIONS ORDERING GUIDE