TABLE I. Electrical performance characteristics - Continued. 1/ Test Test conditions Limits Unit 2/ Min Typ Max TEMPERATURE RANGE Specified Performance -55 +105 °C 1/ Testing and other quality control techniques are used to the extent deemed necessary to assure product performance over the specified temperature range. Product may not necessarily be tested across the full temperature range and all parameters may not necessarily be tested. In the absence of specific parametric testing, product performance is assured by characterization and/or design. 2/ All minimum and maximum specifications are guaranteed. Typical specifications are not guaranteed. TA = 25°C, VS = AVCC = VDD = 6 V, VRATIO = AVCC, angular rate = °/sec, bandwidth = 80 Hz (COUT = 0.01 µF), IOUT = 100 µA, ±1 g, unless otherwise noted. 3/ Parameter is linearly ratio metric with VRATIO. 4/ Measurement range is the maximum range possible, including output swing range, initial offset, sensitivity, offset drift, and sensitivity drift at 5 V supplies. 5/ From +25°C to −40°C or +25°C to +105°C. 6/ Adjusted by external capacitor, COUT. Reducing bandwidth below 0.01 Hz does not result in further noise improvement. 7/ Self-test mismatch is described as (ST2 + ST1)/((ST2 − ST1)/2). 8/ Based on characterization. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/14618 REV PAGE 5 Document Outline DESCRIPTION REV REV PMIC N/A TITLE SIZE A V62/14618 REV