Datasheet ADUM6000 (Analog Devices) - 5

制造商Analog Devices
描述Isolated, 5 kV, DC-to-DC Converter
页数 / 页16 / 5 — Data Sheet. ADuM6000. REGULATORY INFORMATION. Table 6. UL1 CSA. VDE2. …
修订版D
文件格式/大小PDF / 404 Kb
文件语言英语

Data Sheet. ADuM6000. REGULATORY INFORMATION. Table 6. UL1 CSA. VDE2. INSULATION AND SAFETY-RELATED SPECIFICATIONS

Data Sheet ADuM6000 REGULATORY INFORMATION Table 6 UL1 CSA VDE2 INSULATION AND SAFETY-RELATED SPECIFICATIONS

该数据表的模型线

文件文字版本

link to page 5 link to page 8 link to page 15 link to page 5 link to page 5 link to page 5
Data Sheet ADuM6000 REGULATORY INFORMATION
The ADuM6000 is approved by the organizations listed in Table 6. Refer to Table 11 and the Insulation Lifetime section for more information about the recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 6. UL1 CSA VDE2
Recognized under UL 1577 Approved under CSA Component Acceptance Notice #5A RI-16-2 package: component recognition Certified according to DIN V VDE V program 0884-10 (VDE V 0884-10):2006-123 Reinforced insulation, 846 V peak Single protection, 5000 V rms Basic insulation per CSA 60950-1-07 and IEC 60950-1, 600 V rms RW-16 package (pending): isolation voltage (848 V peak) maximum working voltage Certified according to IEC 60747-5-2 (VDE 0884 Part 2):2003-01 Basic insulation, 846 V peak RW-16 package: Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 380 V rms (537 V peak) maximum working voltage Reinforced insulation per IEC 60601-1, 125 V rms (176 V peak) maximum working voltage RI-16-2 package (pending): Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 400 V rms (565 V peak) maximum working voltage Reinforced insulation per IEC 60601-1, 250 V rms (353 V peak) maximum working voltage File E214100 File 205078 File 2471900-4880-0001 1 In accordance with UL 1577, each ADuM6000 is proof-tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage detection limit = 15 μA). 2 In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM6000 is proof-tested by applying an insulation test voltage ≥ 1590 V peak for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884 Part 2):2003-01 approval. 3 In accordance with DIN V VDE V 0884-10, each ADuM6000 is proof-tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS Table 7. Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration Minimum External Air Gap (Clearance) L(I01) 8.0 mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) RW-16 L(I02) 7.6 mm Measured from input terminals to output terminals, Package shortest distance path along body Minimum External Tracking (Creepage) RI-16-2 L(I02) 8.3 min mm Measured from input terminals to output terminals, Package shortest distance path along body Minimum Internal Distance (Internal Clearance) 0.017 min mm Distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303, Part 1 Material Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Rev. D | Page 5 of 16 Document Outline Features Applications General Description Functional Block Diagram Revision History Specifications Electrical Characteristics—5 V Primary Input Supply/5 V Secondary Isolated Supply Electrical Characteristics—3.3 V Primary Input Supply/3.3 V Secondary Isolated Supply Electrical Characteristics—5 V Primary Input Supply/3.3 V Secondary Isolated Supply Package Characteristics Regulatory Information Insulation and Safety-Related Specifications DIN V VDE V 0884-10 (VDE V 0884-10) and IEC 60747-5-2 (VDE 0884 Part 2):2003-01 Insulation Characteristics Thermal Derating Curve Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Applications Information PCB Layout Start-Up Behavior EMI Considerations Thermal Analysis Current Limit and Thermal Overload Protection Power Considerations Increasing Available Power Insulation Lifetime Outline Dimensions Ordering Guide