Datasheet LT1021 (Analog Devices) - 4

制造商Analog Devices
描述Precision Reference
页数 / 页16 / 4 — ELECTRICAL CH. ARA TERISTICS The. denotes specifications that apply over …
文件格式/大小PDF / 239 Kb
文件语言英语

ELECTRICAL CH. ARA TERISTICS The. denotes specifications that apply over the full operating temperature

ELECTRICAL CH ARA TERISTICS The denotes specifications that apply over the full operating temperature

该数据表的模型线

文件文字版本

LT1021
ELECTRICAL CH C ARA TERISTICS The

denotes specifications that apply over the full operating temperature range, otherwise specifications are TA = 25
°
C. VIN = 15V, IOUT = 0, unless otherwise noted. LT1021-10 PARAMETER CONDITIONS MIN TYP MAX UNITS
Output Voltage (Note 2) LT1021C-10 9.995 10.00 10.005 V LT1021B-10/LT1021D-10 9.950 10.00 10.050 V Output Voltage Temperature Coefficient (Note 3) TMIN ≤ TJ ≤ TMAX LT1021B-10 ● 2 5 ppm/°C LT1021C-10/LT1021D-10 ● 5 20 ppm/°C Line Regulation (Note 4) 11.5V ≤ VIN ≤ 14.5V 1.0 4 ppm/V ● 6 ppm/V 14.5V ≤ VIN ≤ 40V 0.5 2 ppm/V ● 4 ppm/V Load Regulation (Sourcing Current) 0 ≤ IOUT ≤ 10mA 12 25 ppm/mA (Note 4) ● 40 ppm/mA Load Regulation (Shunt Mode) 1.7mA ≤ ISHUNT ≤ 10mA 50 100 ppm/mA (Notes 4, 5) ● 150 ppm/mA Supply Current (Series Mode) 1.2 1.7 mA ● 2.0 mA Minimum Current (Shunt Mode) VIN is Open 1.1 1.5 mA ● 1.7 mA Output Voltage Noise (Note 6) 0.1Hz ≤ f ≤ 10Hz 6.0 µVP-P 10Hz ≤ f ≤ 1kHz 3.5 6 µVRMS Long Term Stability of Output Voltage (Note 7) ∆t = 1000Hrs Noncumulative 15 ppm Temperature Hysteresis of Output ∆T = ±25°C 5 ppm
Note 1:
Absolute Maximum Ratings are those values beyond which the life
Note 5:
Shunt mode regulation is measured with the input open. With the of a device may be impaired. input connected, shunt mode current can be reduced to 0mA. Load
Note 2:
Output voltage is measured immediately after turn-on. Changes regulation will remain the same. due to chip warm-up are typically less than 0.005%.
Note 6:
RMS noise is measured with a 2-pole highpass filter at 10Hz and a
Note 3:
Temperature coefficient is measured by dividing the change in 2-pole lowpass filter at 1kHz. The resulting output is full-wave rectified and output voltage over the temperature range by the change in temperature. then integrated for a fixed period, making the final reading an average as Separate tests are done for hot and cold; T opposed to RMS. Correction factors are used to convert from average to MIN to 25°C and 25°C to TMAX.
Incremental slope is also measured at 25
°
C.
RMS and correct for the non-ideal bandpass of the filters.
Note 4:
Line and load regulation are measured on a pulse basis. Output Peak-to-peak noise is measured with a single highpass filter at 0.1Hz and a changes due to die temperature change must be taken into account 2-pole lowpass filter at 10Hz. The unit is enclosed in a still-air environment separately. Package thermal resistance is 150°C/W for TO-5 (H), 130°C/W to eliminate thermocouple effects on the leads. Test time is 10 seconds. for N and 150°C/W for the SO-8.
Note 7:
Consult factory for units with long term stability data. 1021fc 4