RH1499M TABLE 2A: ELECTRICAL CHARACTERISTICS(Postirradiation) VS = 5V; VCM = half supply, TA = 25°C, unless otherwise noted.10Krad (Si)20Krad (Si)50Krad (Si)100Krad (Si) 200Krad (Si)SYMBOL PARAMETERCONDITIONSNOTES MINMAXMINMAXMINMAXMINMAXMINMAX UNITS CMRR Match VCM = V+ to V– 3 70 70 70 70 70 dB (Channel-to-Channel) PSRR Power Supply VS = 4.5V to 12V, 88 88 88 88 88 dB Rejection Ratio VCM = VO = 0.5V PSRR Match VS = 4.5V to 12V, 3 82 82 82 82 82 dB (Channel-to-Channel) VCM = VO = 0.5V VOUT Output Voltage No Load 60 60 60 60 60 mV Swing Low ISINK = 1mA 4 100 100 100 100 100 mV ISINK = 2.5mA 200 200 200 200 200 mV Output Voltage No Load 20 20 20 20 20 mV Swing High ISOURCE = 1mA 4 150 150 150 150 150 mV ISOURCE = 2.5mA 250 250 250 250 250 mV ISC Short-Circuit Current ±8 ±8 ±8 ±8 ±8 mA IS Supply Current 2.2 2.2 2.2 2.2 2.2 mA SR Slew Rate VS = ±2.5V, AV = –1, 2 2 2 2 2 V/µs RL = 10k, VO = ±2V, Measure at VO = ±1V Note 1: Stresses beyond those listed under Absolute Maximum Ratings Note 3: Matching parameters are the difference between amplifiers A and may cause permanent damage to the device. Exposure to any Absolute D and between B and C. Maximum Rating condition for extended periods may affect device Note 4: Output voltage swings are measured between the output and reliability and lifetime. power supply rails. Note 2: A heat sink may be required to keep the junction temperature below this absolute maximum rating when the output is shorted indefinitely. TABLE 2: ELECTRICAL TEST REQUIREMENTS MIL-STD-883 TEST REQUIREMENTSSUBGROUPPDA Test Notes Final Electrical Test Requirements (Method 5004) 1*,2,3,4,5,6 The PDA is specified as 5% based on failures from group A, subgroup 1, tests after cooldown as the final electrical test in accordance with method Group A Test Requirements (Method 5005) 1,2,3,4,5,6 5004 of MIL-STD-883. The verified failures of group A, subgroup 1, after Group B and D for Class S, and 1,2,3 burn-in divided by the total number of devices submitted for burn-in in End Point Electrical Parameters (Method 5005) that lot shall be used to determine the percent for the lot. *PDA applies to subgroup 1. See PDA Test Notes. Linear Technology Corporation reserves the right to test to tighter limits than those given. TOTAL DOSE BIAS CIRCUIT 40pF 5k 15V – 5k 8V + –15V RH1499 TC rh1499mfg For more information www.linear.com/RH1499M 5 Document Outline Description Absolute Maximum Ratings Burn-In Circuit Package Information Table 1: Electrical Characteristics Table 1A: Electrical Characteristics Table 2: Electrical Characteristics Table 2A: Electrical Characteristics Table 2: Electrical Test Requirements Total Dose Bias Circuit Typical Performance Characteristics