LTC3707-SYNC ELECTRICAL CHARACTERISTICSThe l denotes the specifi cations which apply over the full operatingtemperature range, otherwise specifi cations are at TA = 25°C. VIN = 15V, VRUN/SS1, 2 = 5V unless otherwise noted.SYMBOLPARAMETERCONDITIONSMINTYPMAXUNITS IPLLFLTR Phase Detector Output Current Sinking Capability fPLLIN < fOSC –15 μA Sourcing Capability fPLLIN > fOSC 15 μA 3.3V Linear Regulator V3.3OUT 3.3V Regulator Output Voltage No Load l 3.20 3.35 3.45 V V3.3IL 3.3V Regulator Load Regulation I3.3 = 0 to 10mA 0.5 2 % V3.3VL 3.3V Regulator Line Regulation 6V < VIN < 30V 0.05 0.2 % PGOOD Output VPGL PGOOD Voltage Low IPGOOD = 2mA 0.1 0.3 V IPGOOD PGOOD Leakage Current VPGOOD = 5V ±1 μA VPG PGOOD Trip Level, Either Controller VOSENSE with Respect to Set Output Voltage VOSENSE Ramping Negative –6 –7.5 –9.5 % VOSENSE Ramping Positive 6 7.5 9.5 % Note 1: Stresses beyond those listed under Absolute Maximum Ratings Note 4: The IC is tested in a feedback loop that servos VITH1, 2 to a may cause permanent damage to the device. Exposure to any Absolute specifi ed voltage and measures the resultant VOSENSE1, 2. Maximum Rating condition for extended periods may affect device Note 5: Dynamic supply current is higher due to the gate charge being reliability and lifetime. delivered at the switching frequency. See Applications Information. Note 2: The LTC3707E-SYNC is guaranteed to meet performance Note 6: Rise and fall times are measured using 10% and 90% levels. specifi cation from 0°C to 85°C. Specifi cations over the –40°C to 85°C Delay times are measured using 50% levels. operating temperature range are assured by design, characterization Note 7: The minimum on-time condition is specifi ed for an inductor and correlation with statistical process controls. The LTC3707I-SYNC peak-to-peak ripple current ≥40% of IMAX (see minimum on-time is guaranteed to meet performance specifi cations over the full –40°C considerations in the Applications Information section). to 85°C operating temperature range. Note 3: TJ is calculated from the ambient temperature TA and power dissipation PD according to the following formulas: LTC3707-SYNC: TJ = TA + (PD • 95 °C/W) TYPICAL PERFORMANCE CHARACTERISTICSEffi ciency vs Output CurrentEffi ciency vs Output CurrentEffi ciency vs Input Voltageand Mode (Figure 13)(Figure 13)(Figure 13) 100 100 100 Burst Mode V 90 IN = 7V OPERATION 80 90 90 70 VIN = 10V FORCED VIN = 15V 60 CONTINUOUS 80 80 MODE 50 VIN = 20V 40 CONSTANT 70 70 EFFICIENCY (%) EFFICIENCY (%) EFFICIENCY (%) 30 FREQUENCY (BURST DISABLE) 20 60 60 10 V V IN = 15V OUT = 5V V I OUT = 5V VOUT = 5V OUT = 3A 0 50 50 0.001 0.01 0.1 1 10 0.001 0.01 0.1 1 10 5 15 25 35 OUTPUT CURRENT (A) OUTPUT CURRENT (A) INPUT VOLTAGE (V) 3707 G01 3707 G02 3707 G03 3707sfa 4