Datasheet ACS711 (Allegro) - 7

制造商Allegro
描述Hall Effect Linear Current Sensor with Overcurrent Fault Output for <100 V Isolation Applications
页数 / 页18 / 7 — Hall-Effect Linear Current Sensor with. ACS711. Overcurrent Fault Output …
文件格式/大小PDF / 1.1 Mb
文件语言英语

Hall-Effect Linear Current Sensor with. ACS711. Overcurrent Fault Output for < 100 V Isolation Applications

Hall-Effect Linear Current Sensor with ACS711 Overcurrent Fault Output for < 100 V Isolation Applications

该数据表的模型线

文件文字版本

Hall-Effect Linear Current Sensor with ACS711 Overcurrent Fault Output for < 100 V Isolation Applications THERMAL CHARACTERISTICS Characteristic Symbol Test Conditions [1] Value Units
Package Thermal Resistance, LC package, mounted on Allegro ASEK 711 evalua- Junction to Lead RθJL tion board 5 °C/W LC package, mounted on Allegro 85-0404 evaluation Package Thermal Resistance, board, includes the power consumed by the board 23 °C/W Junction to Ambient [2] RθJA EX package, mounted on Allegro 85-0528 evaluation board, includes the power consumed by the board 24 °C/W [1] Additional thermal information available on the Allegro website. [2] The Allegro evaluation board has 1500 mm2 of 2 oz. copper on each side, connected to pins 1 and 2, and to pins 3 and 4, with thermal vias connecting the layers. Performance values include the power consumed by the PCB. Further details on the board are available from the Frequently Asked Questions document on our website. Allegro MicroSystems, LLC 7 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com