link to page 5 ADM3053Data SheetVDE 0884 INSULATION CHARACTERISTICS This isolator is suitable for basic electrical isolation only within the safety limit data. Maintenance of the safety data must be ensured by means of protective circuits. Table 5. DescriptionTest Conditions/CommentsSymbol Characteristic Unit CLASSIFICATIONS Installation Classification per DIN VDE 0110 for Rated Mains Voltage ≤150 V rms I to IV ≤300 V rms I to III ≤400 V rms I to II Climatic Classification 40/85/21 Pollution Degree DIN VDE 0110, see Table 3 2 VOLTAGE Maximum Working Insulation Voltage VIORM 560 VPEAK Input-to-Output Test Voltage VPR Method b1 VIORM × 1.875 = VPR, 100% production tested, 1050 VPEAK tm = 1 sec, partial discharge < 5 pC Highest Allowable Overvoltage (Transient overvoltage, tTR = 10 sec) VTR 4000 VPEAK SAFETY-LIMITING VALUES Maximum value allowed in the event of a failure Case Temperature TS 150 °C Input Current IS, INPUT 265 mA Output Current IS, OUTPUT 335 mA Insulation Resistance at TS VIO = 500 V RS >109 Ω Rev. E | Page 6 of 18 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS TIMING SPECIFICATIONS SWITCHING CHARACTERISTICS REGULATORY INFORMATION INSULATION AND SAFETY-RELATED SPECIFICATIONS VDE 0884 INSULATION CHARACTERISTICS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS CIRCUIT DESCRIPTION CAN TRANSCEIVER OPERATION SIGNAL ISOLATION POWER ISOLATION TRUTH TABLES THERMAL SHUTDOWN DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY APPLICATIONS INFORMATION PCB LAYOUT EMI CONSIDERATIONS RS PIN INSULATION LIFETIME TYPICAL APPLICATIONS OUTLINE DIMENSIONS ORDERING GUIDE