link to page 5 Enhanced ProductADuM3221-EPPACKAGE CHARACTERISTICSTable 3. ParameterSymbol MinTypMaxUnitTest Conditions/Comments Resistance (Input to Output)1 R 1012 Ω I-O Capacitance (Input to Output)1 C 1.0 pF f = 1 MHz I-O Input Capacitance C 4.0 pF I IC Junction to Case Thermal Resistance, Side 1 θ 46 °C/W Thermocouple located at center JCI of package underside IC Junction to Case Thermal Resistance, Side 2 θ 41 °C/W Thermocouple located at center JCO of package underside IC Junction to Ambient Thermal Resistance θ 85 °C/W Thermocouple located at center JA of package underside 1 The device is considered a 2-terminal device; Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together. REGULATORY INFORMATION The ADuM3221-EP is approved by the organizations listed in Table 4. Table 4. ULCSA (Pending)VDE (Pending) Recognized Under UL 1577 Approved under CSA Component Acceptance Notice 5A Certified according to DIN V VDE V 0884-10 Component Recognition (VDE V 0884-10):2006-122 Program1 Single/Basic 2500 V rms Basic insulation per CSA 60950-1-03 and IEC 60950-1, Reinforced insulation, 560 V peak Isolation Voltage 400 V rms (566 V peak) maximum working voltage Functional insulation per CSA 60950-1-03 and IEC 60950-1, 800 V rms (1131 V peak) maximum working voltage File E214100 File 205078 File 2471900-4880-0001 1 In accordance with UL 1577, each ADuM3221-EP is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 µA). 2 In accordance with DIN V VDE V 0884-10, each ADuM3221-EP is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval. INSULATION AND SAFETY RELATED SPECIFICATIONSTable 5. ParameterSymbolValueUnitTest Conditions/Comments Rated Dielectric Insulation Voltage 2500 V rms 1 minute duration Minimum External Air Gap (Clearance) L(I01) 4.90 min mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L(I02) 4.01 min mm Measured from input terminals to output terminals, shortest distance path along body Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1 Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Rev. 0 | Page 5 of 12 Document Outline FEATURES ENHANCED PRODUCT FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V OPERATION ELECTRICAL CHARACTERISTICS—3.3 V OPERATION PACKAGE CHARACTERISTICS REGULATORY INFORMATION INSULATION AND SAFETY RELATED SPECIFICATIONS DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS RECOMMENDED OPERATING CONDITIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS OUTLINE DIMENSIONS ORDERING GUIDE