link to page 5 link to page 9 link to page 5 link to page 5 link to page 5 Data SheetADuM1233DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS This isolator is suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by protective circuits. The asterisk (*) marking on the package denotes DIN V VDE V 0884-10 approval for a 560 V peak working voltage. Table 5. DescriptionTest Conditions/CommentsSymbolCharacteristic Unit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to III For Rated Mains Voltage ≤ 400 V rms I to II Climatic Classification 40/105/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage VIORM 560 V peak Input-to-Output Test Voltage, Method B1 VIORM × 1.875 = Vpd(m), 100% production test, Vpd(m) 1050 V peak tini = tm = 1 sec, partial discharge < 5 pC Input-to-Output Test Voltage, Method A After Environmental Tests Subgroup 1 VIORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec, Vpd(m) 896 V peak partial discharge < 5 pC After Input and/or Safety Tests Subgroup 2 VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec, Vpd(m) 672 V peak and Subgroup 3 partial discharge < 5 pC Highest Allowable Overvoltage VIOTM 4000 V peak Surge Isolation Voltage V peak = 10 kV, 1.2 µs rise time, 50 µs, 50% fal time VIOSM 4000 V peak Safety-Limiting Values Maximum value allowed in the event of a failure (see Figure 2) Case Temperature TS 150 °C Safety Total Dissipated Power PS 1 W Insulation Resistance at TS VIO = 500 V RS >109 Ω 1.2RECOMMENDED OPERATING CONDITIONS1.0W)Table 6.( RParameterSymbol Min MaxUnitOWE 0.8 Operating Temperature TA −40 +105 °C G P Input Supply Voltage1 VDD1 4.5 5.5 V ITIN 0.6 Output Supply Voltages1 VDDA, 12 18 V LIM VDDB FE A 0.4 Input Signal Rise and Fall Times 100 ns S Common-Mode Transient 0.2 Immunity Input-to-Output2 −75 +75 kV/µs 0 Between Outputs2 −75 +75 kV/µs 050100150200 102 Transient Immunity, Supply −75 +75 kV/µs AMBIENT TEMPERATURE (°C) 06271- Voltages2 Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values on Case Temperature, per DIN V VDE V 0884-10 1 All voltages are relative to their respective ground. 2 See the Common-Mode Transient Immunity section for more information. Rev. C | Page 5 of 12 Document Outline Features Applications General Description Functional Block Diagram Table of Contents Revision History Specifications Electrical Characteristics Package Characteristics Regulatory Information Insulation and Safety-Related Specifications DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Perfomance Characteristics Applications Information Common-Mode Transient Immunity Outline Dimensions Ordering Guide