Datasheet G7EB (Omron)

制造商Omron
描述PCB Power Relays. High Power and high temperature type Power Relay with 480 VAC 100 A current
页数 / 页4 / 1 — High Power and high temperature type Power Relay with 480 VAC 100 A …
文件格式/大小PDF / 1.2 Mb
文件语言英语

High Power and high temperature type Power Relay with 480 VAC 100 A current. RoHS Compliant. Model Number Legend

Datasheet G7EB Omron

该数据表的模型线

文件文字版本

G7EB PCB Power Relays
High Power and high temperature type Power Relay with 480 VAC 100 A current
• 480 VAC/100 A high current switching capable • Ambient temperature 85°C • High impulse withstand voltage, 10 kV • Contact gap ≥3.6 mm (Applied to VDE0126) • Low initial contact resistance ≥5 mΩ
RoHS Compliant Model Number Legend Application Examples
• Power conditioner inverter
G7EB-
 1 2 3 • Industrial inverter • UPS 1. Number of Poles 2. Contact Form 3. Terminal Shape G 1: 1-pole A: SPST-NO (1a) None: Standard type 7 P1: Special terminal type E B
Ordering Information
Terminal shape Contact form Enclosure rating Model Rated coil voltage (V) Minimum packing unit Standard G7EB-1A 12 VDC SPST-NO (1a) Flux protection 60pcs/box 24 VDC Special G7EB-1AP1 Note. When ordering, add the rated coil voltage to the model number. Example: G7EB-1A DC12 Rated coil voltage Both the coil voltage on the product case and the packing will be marked as VDC.
Raitings Coil
Must operate voltage Must release voltage Max. voltage Rated current Coil resistance Rated voltage (V) (V) (V) Power consumption (mA) (Ω) (mW) % of rated voltage 12 VDC Approx. 235.3 51 120% Approx. 2,800 75% max. * 5 to 32% (at 23°C) Approx. 575 * 24 VDC Approx. 116.5 206 Note 1. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the relay coil operating power supply and was measured at an ambient temperature of 23°C. * Power consumption with Holding Voltage is approx. 575 mW (when applying Holding Voltage at 45%). Please confirm the detail in page 4 Coil Voltage Reduction (Holding Voltage) after Relay Operation. * Some mounting direction is out of guarantee. Please confirm the detail in page 4 Mounting Direction.
Contacts
Item Resistive load Contact type Double Contact material Ag Alloy (Cd free) 100 A at 480 VAC Rated load 40 A at 800 VAC Rated carry current 100 A Max. switching voltage AC 800 V Max. switching current 100 A