Coreless, High Precision, Hall-Effect Current Sensor ICACS37612with Common-Mode Field Rejection and High Bandwidth (240 kHz)ABSOLUTE MAXIMUM RATINGSCharacteristicSymbolNotesRatingUnit Supply Voltage VCC 6.5 V Reverse Supply Voltage VRCC –0.5 V Output Voltage VIOUT 6.5 V Reverse Output Voltage VRIOUT –0.5 V Output Source Current IOUT(Source) VOUT to GND 3 mA Output Sink Current IOUT(Sink) Minimum pull-up resistor of 500 Ω 10 mA Nominal Operating Ambient Temperature TA Range L –40 to 150 °C Maximum Junction Temperature TJ(max) 165 °C Storage Temperature Tstg –65 to 165 °C ESD RATINGSCharacteristicSymbolTest ConditionsValueUnit Human Body Model VHBM Per AEC-Q100 ±12 kV Charged Device Model VCDM Per AEC-Q100 ±1 kV THERMAL CHARACTERISTICS: May require derating at maximum conditions; see application informationCharacteristicSymbolTest Conditions*ValueUnit Package Thermal Resistance RθJA LU package, on 4-layer PCB based on JEDEC standard 145 °C/W *Additional thermal information available on the Allegro website VCC OUT OUT VCC CBYPASS C 0.1 µF L ACS37612 GND Figure 3: Typical Application CircuitThe ACS37612 outputs an analog signal, VOUT, that varies linearly with the bi-directional AC or DC field sensed within the range specified. CL is for optimalnoise management, with values that depend on the application. 3 Allegro MicroSystems 955 Perimeter Road Manchester, NH 03103-3353 U.S.A. www.allegromicro.com