Datasheet ADP1071-1, ADP1071-2 (Analog Devices) - 7

制造商Analog Devices
描述Isolated Synchronous Flyback Controller with Integrated iCoupler
页数 / 页27 / 7 — Data Sheet. ADP1071-1. /ADP1071-2. REGULATORY INFORMATION
修订版B
文件格式/大小PDF / 577 Kb
文件语言英语

Data Sheet. ADP1071-1. /ADP1071-2. REGULATORY INFORMATION

Data Sheet ADP1071-1 /ADP1071-2 REGULATORY INFORMATION

该数据表的模型线

文件文字版本

link to page 7 link to page 23 link to page 7
Data Sheet ADP1071-1 /ADP1071-2 REGULATORY INFORMATION
See Table 3, Table 4, and the Insulation Lifetime section for details regarding recommended maximum working voltages for specific cross isolation waveforms and insulation levels.
Table 3. Regulatory Information for Wide Body SOIC Package UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending)
Recognized Under UL 1577 Approved under CSA Component Certified according to DIN V VDE V Certified by Component Recognition Acceptance Notice 5A 0884-10 (VDE V 0884-10):2006-122 CQC11-471543-2012, Program1 GB4943.1-2011: Single Protection, 5000 V rms CSA 60950-1-07+A1+A2 and IEC 60950-1, Reinforced insulation, VIORM = Basic insulation at Isolation Voltage second edition, +A1+A2: 849 peak, VIOTM = 8000 V peak 780 V rms (1103 V peak) Basic insulation at 780 V rms (1103 V peak) Reinforced insulation at 389 V rms (552 V peak), Reinforced insulation at 390 V rms tropical climate, (552 V peak) altitude ≤ 5000 meters IEC 60601-1 Edition 3.1: Basic insulation (1 means of patient protection (1 MOPP)), 490 V rms (686 V peak) Reinforced insulation (2 MOPP), 238 V rms (325 V peak) CSA 61010-1-12 and IEC 61010-1 third edition: Basic insulation at 300 V rms mains, 780 V secondary (1103 V peak) File E214100 File 205078 File 2471900-4880-0001 File (pending) 1 In accordance with UL 1577, each product is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec. 2 In accordance with DIN V VDE V 0884-10, each product is proof tested by applying an insulation test voltage ≥ 1592 V peak for 1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Table 4. Regulatory Information for LGA Package UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending)
Recognized Under UL 1577 Approved under CSA Component Certified according to DIN V VDE V Certified by Component Recognition Acceptance Notice 5A 0884-10 (VDE V 0884-10):2006-122 CQC11-471543-2012, Program1 GB4943.1-2011: Single Protection, 3000 V rms CSA 60950-1-07+A1+A2 and IEC 60950-1, Reinforced insulation, VIORM = Basic insulation at Isolation Voltage second edition, +A1+A2: 565 V peak, VIOTM = 4242 V peak 400 V rms (565 V peak) impulse voltage = 4242 V peak Basic insulation at 400 V rms (565 V peak) Reinforced insulation at 200 V rms (283 V peak), Reinforced insulation at 200 V rms tropical climate, (283 V peak) altitude ≤ 5000 meters IEC 60601-1 Edition 3.1: Basic insulation (1 means of patient protection (1 MOPP)), 250 V rms (354 V peak) CSA 61010-1-12 and IEC 61010-1 third edition: Basic insulation at 300 V rms mains, 400 V secondary (565 V peak) File (pending) File (pending) File (pending) File (pending) 1 In accordance with UL 1577, each product is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec. 2 In accordance with DIN V VDE V 0884-10, each product is proof tested by applying an insulation test voltage ≥ 1059 V peak for 1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval. Rev. B | Page 7 of 27 Document Outline Features Applications Functional Block Diagram General Description Revision History Specifications Insulation and Safety Related Specifications Regulatory Information Absolute Maximum Ratings Thermal Resistance ESD Caution Pin Configurations and Function Descriptions Typical Performance Characteristics Theory of Operation Detailed Block Diagram Primary Side Supply, Input Voltage, and LDO Secondary Side Supply and LDO Precision Enable Soft Start Procedure Output Voltage Sensing and Feedback Loop Compensation and Steady State Operation Slope Compensation Input/Output Current-Limit Protection Temperature Sensing Frequency Setting (RT Pin) Maximum Duty Cycle Frequency Synchronization Synchronous Rectifier (SR) Driver Output Overvoltage Protection (OVP) SR Dead Time Light Load Mode (LLM) and Continuous Conduction Mode (CCM) Soft Stop OCP/Feedback Recovery Output Voltage Tracking Remote System Reset OCP Counter External Start-Up Circuit Insulation Lifetime Layout Guidelines Applications Information Typical Application Circuits Outline Dimensions Ordering Guide