link to page 9 link to page 15 Data SheetADuM6020/ADuM6028PACKAGE CHARACTERISTICSTable 10. ADuM6020 Package Characteristics ParameterSymbol Min TypMax Unit TestConditions/Comments Resistance (Input to Output)1 RI-O 1013 Ω Capacitance (Input to Output)1 CI-O 2.2 pF f = 1 MHz Input Capacitance2 CI 4.0 pF IC Junction to Ambient Thermal θJA 45 °C/W Thermocouple located at center of package Resistance underside3 1 This device is considered a 2-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together. 2 Input capacitance is from any input data pin to ground. 3 The value of θJA is based on devices mounted on a JEDEC JESD-51 standard 2s2p board and still air. Table 11. ADuM6028 Package Characteristics ParameterSymbol Min TypMax Unit TestConditions/Comments Resistance (Input to Output)1 RI-O 1013 Ω Capacitance (Input to Output)1 CI-O 2.2 pF f = 1 MHz Input Capacitance2 CI 4.0 pF IC Junction to Ambient Thermal θJA 80 °C/W Thermocouple located at center of package Resistance underside3 1 This device is considered a 2-terminal device: Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together. 2 Input capacitance is from any input data pin to ground. 3 The value of θJA is based on devices mounted on a JEDEC JESD-51 standard 2s2p board and still air. DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by the protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval. Table 12. ADuM6020 VDE Characteristics Description TestConditions/Comments SymbolCharacteristicUnit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to III For Rated Mains Voltage ≤ 400 V rms I to II Climatic Classification 40/125/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage VIORM 565 V peak Input to Output Test Voltage, Method b1 VIORM × 1.875 = VPR, 100% production test, tm = 1 sec, VPR 1059 V peak partial discharge < 5 pC Input to Output Test Voltage, Method a VPR After Environmental Tests Subgroup 1 VIORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec, Vpd(m) 848 V peak partial discharge < 5 pC After Input or Safety Test Subgroup 2 VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec, Vpd(m) 678 V peak and Subgroup 3 partial discharge < 5 pC Highest Allowable Overvoltage Transient overvoltage, tTR = 10 sec VIOTM 8000 V peak Withstand Isolation Voltage 1 minute withstand rating VISO 5000 V rms Surge Isolation Voltage Reinforced VIOSM(TEST) = 10 kV; 1.2 μs rise time; 50 μs, 50% fall time VIOSM 6250 V peak Safety Limiting Values Maximum value allowed in the event of a failure (see Figure 3) Case Temperature TS 150 °C Total Power Dissipation at 25°C IS1 2.78 W Insulation Resistance at TS VIO = 500 V RS >109 Ω Rev. B | Page 7 of 20 Document Outline Features Applications Functional Block Diagrams General Description Revision History Specifications Electrical Characteristics—5 V Primary Input Supply/5 V Secondary Isolated Supply Electrical Characteristics—5 V Primary Input Supply/3.3 V Secondary Isolated Supply Electrical Characteristics—3.3 V Primary Input Supply/3.3 V Secondary Isolated Supply Regulatory Approvals Insulation and Safety Related Specifications Package Characteristics DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Truth Table Typical Performance Characteristics Theory of Operation Applications Information PCB Layout Thermal Analysis EMI Considerations Insulation Lifetime Surface Tracking Insulation Wear Out Calculation and Use of Parameters Example Outline Dimensions Ordering Guide