link to page 9 link to page 20 link to page 9 link to page 13 link to page 13 link to page 13 link to page 14 link to page 14 Data SheetADuM5210/ADuM5211/ADuM5212PACKAGE CHARACTERISTICSTable 15. Thermal and Isolation Characteristics ParameterSymbol Min Typ Max Unit TestConditions/Comments Resistance (Input to Output)1 RI-O 1012 Ω Capacitance (Input to Output)1 CI-O 2.2 pF f = 1 MHz Input Capacitance2 CI 4.0 pF IC Junction-to-Ambient Thermal Resistance θJA 50 °C/W Thermocouple located at center of package underside, test conducted on 4-layer board with thin traces3 1 The device is considered a 2-terminal device: Pin 1 through Pin 10 are shorted together, and Pin 11 through Pin 20 are shorted together. 2 Input capacitance is from any input data pin to ground. 3 See the Thermal Analysis section for thermal model definitions. REGULATORY APPROVALSTable 16. UL1CSA VDE2 Recognized under 1577 Component Approved under CSA Component Certified according to DIN V VDE V 0884-10 Recognition Program1 Acceptance Notice 5A (VDE V 0884-10):2006-122 Single Protection, 2500 V RMS Basic insulation per CSA 60950-1-03 Reinforced insulation, 560 V peak Isolation Voltage and IEC 60950-1, 400 V rms (565 V peak) maximum working voltage File E214100 File 205078 File 2471900-4880-0001 1 In accordance with UL 1577, each ADuM5210/ADuM5211/ADuM5212 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 10 μA). 2 In accordance with DIN V VDE V 0884-10, each ADuM5210/ADuM5211/ADuM5212 is proof tested by applying an insulation test voltage ≥1590 V peak for 1 second (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval. INSULATION AND SAFETY-RELATED SPECIFICATIONSTable 17. Critical Safety-Related Dimensions and Material Properties Parameter SymbolValueUnitTestConditions/Comments Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration Minimum External Air Gap (Clearance) L(I01) 5.3 mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L(I02) 5.3 mm Measured from input terminals to output terminals, shortest distance path along body Minimum Internal Gap (Internal Clearance) 0.017 min mm Distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303, Part 1 Isolation Group II Material group (DIN VDE 0110, 1/89, Table 1) Rev. D | Page 9 of 23 Document Outline FEATURES APPLICATIONS FUNCTIONAL BLOCK DIAGRAM GENERAL DESCRIPTION TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/5 V SECONDARY ISOLATED SUPPLY ELECTRICAL CHARACTERISTICS—3.3 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY PACKAGE CHARACTERISTICS REGULATORY APPROVALS INSULATION AND SAFETY-RELATED SPECIFICATIONS DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS RECOMMENDED OPERATING CONDITIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS TRUTH TABLE TYPICAL PERFORMANCE CHARACTERISTICS APPLICATIONS INFORMATION PCB LAYOUT THERMAL ANALYSIS PROPAGATION DELAY PARAMETERS EMI CONSIDERATIONS DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY POWER CONSUMPTION INSULATION LIFETIME OUTLINE DIMENSIONS ORDERING GUIDE