Datasheet GP2Y0A41SK0F (Sharp) - 7

制造商Sharp
描述Distance Measuring Sensor Unit Measuring distance: 4 to 30 cm Analog output type
页数 / 页9 / 7 — GP2Y0A41SK0F. Notes
文件格式/大小PDF / 1.8 Mb
文件语言英语

GP2Y0A41SK0F. Notes

GP2Y0A41SK0F Notes

该数据表的模型线

文件文字版本

GP2Y0A41SK0F Notes
[Advice for the optics] Lens of this device shall be kept cleanly. There are cases that dust, water or oil and so on deteriorate the characteristics of this device. Please consider in actual application. In case that protection is set in front of the emitter and detector portion, the protection cover which has the most efficient transmittance at the emitting wavelength range of LED for this product ( =870nm±70nm), shall be recommended to use. The face and back of protection cover should be mirror polishing. Also, as there are cases that the characteristics may not be satisfied with according to the distance between the protection cover and this product or the thickness of the protection cover, please use this product after confirming the operation sufficiently in actual application. [Advice for the characteristics] In case that there is an object near to light exits of the sensor between the sensor and the detected object, please use this device after confirming sufficiently what the characteristics of this sensor do not change by the object. When the detector surface receive direct light from the sun, tungsten lamp and so on, there are cases that it can not measure the distance exactly. Please consider the design that the detector does not receive direct light from such light source. Distance between sensor and mirror reflector can not sometimes measure exactly. In case of changing the mounting angle of this product, it may measure the distance exactly. In case that reflective object has boundary line clearly, there is cases that distance can not measure exactly. At that time, if direction of boundary line and the line between emitter center and detector center parallels, it is possible to decrease deviation of measuring distance. (Incorrect) (Correct) In order to decrease measuring error by moving direction of object, we recommend to mount the sensor like below drawing. (Incorrect) (Correct) (Moving direction) (Moving direction) In order to stabilize power supply line, we recommend to connect a by-pass capacitor of 10 F or more between Vcc and GND near this product. [Notes on handling] ystem and so on. Please confirm resistance to chemicals under the actual usage since this product has not been designed against for washing. There are some possibilities that the sensor inside the case package with lens may be exposed to the excessive mechanical stress. Please be careful not to cause any excessive pressure on the case package with lens and also on the PCB at the assembly and inserting of the set. Sheet No.: OP13008EN 7