Datasheet PA22 (Apex) - 5

制造商Apex
描述High Voltage Power Operational Amplifiers
页数 / 页14 / 5 — PA22. INPUT. Parameter. Test Conditions. Min. Typ. Max. Units. GAIN
文件格式/大小PDF / 3.1 Mb
文件语言英语

PA22. INPUT. Parameter. Test Conditions. Min. Typ. Max. Units. GAIN

PA22 INPUT Parameter Test Conditions Min Typ Max Units GAIN

该数据表的模型线

文件文字版本

PA22 INPUT Parameter Test Conditions Min Typ Max Units
Offset Voltage, initial 5 20 mV Offset Voltage vs. Temperature1 25 °C to 85 °C 90 250 µV/°C Offset Voltage vs. Supply 22 50 µV/V Offset Voltage vs. Time 130 µV/kh Bias Current, initial2 100 2000 pA Bias Current vs. Supply 4 pA/V Offset Current, initial 50 2000 pA Input Impedance, DC 1011 Ω Input Capacitance 4 pF Common Mode Voltage Range1 -VS+15 +Vs-15 V Common Mode Rejection, DC VCM= ± 43.5 V 74 108 dB Noise 10 kHz, RI=1 kΩ 13 nV/√Hz 1. Guaranteed but not tested. 2. Doubles for every 10 °C of case temperature increase.
GAIN Parameter Test Conditions Min Typ Max Units
A Large Signal Bandwidth1, 2 v=-100, RLOAD= 1 kΩ, VOUT=220 VPP, ±VS=±125 V 28 kHz Gain Bandwidth Product F=1 MHz 5.8 MHz PSRR, DC Referred to input 80 104 dB 1. Guaranteed but not tested. 2. Calculated from minimum slew rate. PA22 REV B 5 Document Outline Features Applications Description Figure 1: Equivalent Schematic Typical Connection Figure 2: Typical Connection Pinout and Description Table Figure 3: External Connections Specifications Absolute Maximum Ratings Input Gain Output Power Supply Thermal Figure 14: Temp Sense vs Time General Safe operating area (SOA) Figure 15: Safe Operating Area (SOA) typical application Figure 16: Typical Application Schematic current limit overvoltage protection Figure 17: Overvoltage Protection power supply bypassing phase Compensation Temperature Sense Package Options Package Outline (Style LL)