Datasheet MLX90614 (Melexis) - 3

制造商Melexis
描述Single and Dual Zone Infra Red Thermometer in TO-39
页数 / 页57 / 3 — MLX90614 family
文件格式/大小PDF / 2.9 Mb
文件语言英语

MLX90614 family

MLX90614 family

该数据表的模型线

MLX90614

文件文字版本

MLX90614 family
Single and Dual Zone Infra Red Thermometer in TO-39 The PWM pin can also be configured to act as a thermal relay (input is To), thus allowing for an easy and cost effective implementation in thermostats or temperature (freezing / boiling) alert applications. The temperature threshold is user programmable. In a SMBus system this feature can act as a processor interrupt that can trigger reading all slaves on the bus and to determine the precise condition. The thermometer is available in 2 supply voltage options: 5V compatible or 3V (battery) compatible. The 5V can be easily adopted to operate from a higher supply voltage (8…16V, for example) by use of few external components (refer to “Applications information” section for details). An optical filter (long-wave pass) that cuts off the visible and near infra-red radiant flux is integrated in the package to provide ambient and sunlight immunity. The wavelength pass band of this optical filter is from 5.5…14µm (except for xCH and xCI type of devices which incorporate uncoated silicon lens). REVISION 13 - 13 SEPTEMBER 2019 Page 3 of 57 3901090614