User Manual DEPG0266RWS800F34 (DKE) - 4

制造商DKE
描述EPD Module
页数 / 页33 / 4 — 1. Over View. 2. Features
文件格式/大小PDF / 1.3 Mb
文件语言英语

1. Over View. 2. Features

1 Over View 2 Features

该数据表的模型线

文件文字版本

EPD Module User Manual
1. Over View
DEPG0266RWS800F34 is an Active Matrix Electrophoretic Display (AM EPD), with interface and a reference system design. The display is capable to display images at 1-bit white, black and red full display capabilities. The 2.66 inch active area contains 296×152 pixels. The module is a TFT-array driving electrophoresis display, with integrated circuits including gate driver, source driver, MCU interface, timing controller, oscillator, DC-DC, SRAM, LUT, VCOM. Module can be used in portable electronic devices, such as Electronic Shelf Label (ESL) System.
2. Features
◆296×152pixels display ◆High contrast High reflectance ◆Ultra wide viewing angle Ultra low power consumption ◆Pure reflective mode ◆Bi-stable display ◆Commercial temperature range ◆Landscape portrait modes ◆Hard-coat antiglare display surface ◆Ultra Low current deep sleep mode ◆On chip display RAM ◆Waveform can stored in On-chip OTP or written by MCU ◆Serial peripheral interface available ◆On-chip oscillator ◆On-chip booster and regulator control for generating VCOM, Gate and Source driving voltage ◆I2C signal master interface to read external temperature sensor ◆Built-in temperature sensor DKE CO.,LTD Page 4of33 Document Outline Update: 13. Packaging 1. Over View 2. Features 3. Mechanical and Optical Specification . 4.Mechanical Drawing of EPD Module 5. Input/output Pin Assignment 6. Electrical Characteristics 6.1 Absolute Maximum Rating 6.2 Panel DC Characteristics 6.3 Panel DC Characteristics(Driver IC Internal Re Notes:VGH,VGL,VSH,VSL drop voltage<2V. 6.4 Panel AC Characteristics 6.4.1 MCU Interface Selection 6.4.2 MCU Serial Interface (4-wire SPI) 6.4.3 MCU Serial Interface (3-wire SPI) 6.4.4 Interface Timing 7.Command Table 9. Typical Application Circuit with SPI Interface 10.Typical Operating Sequence 10.1 LUT from OTP Operation Flow 10.2 LUT from OTP Operation Reference Program Code ACTION VALUE/DATA COMMENT POWER ON 3v delay 10ms PIN CONFIG RESE# low Hardware reset delay 200us RESE# high delay 200us Read busy pin Wait for busy low Command 0x12 Software reset Read busy pin Wait for busy low SET VOLTAGE AND LOAD LUT LOAD IMAGE AND UPDATE Command 0x24 5624bytes Load BW image (152/8*296)(BW) Command 0x26 5624bytes Load image (152/8*296) (RED) Command 0x20 Read busy pin Wait for busy low Command 0x10 Data 0X01 Enter deep sleep mode POWER OFF 11. Reliability Test 12. Quality Assurance 12.1 Environment 12.2 Illuminance 12.3 Inspect method 12.4 Display area 12.5 Ghosting test method 12.6 Inspection items and acceptance criteria 12.6.1Electric defect 12.6.2 Visual defect 13.Packaging 14. Handling, Safety, and Environment Requirement