Datasheet MOC8101, MOC8102, MOC8103, MOC8104 (Vishay) - 3

制造商Vishay
描述Optocoupler, Phototransistor Output, no Base Connection
页数 / 页7 / 3 — MOC8101, MOC8102, MOC8103, MOC8104. CURRENT TRANSFER RATIO. PARAMETER. …
文件格式/大小PDF / 168 Kb
文件语言英语

MOC8101, MOC8102, MOC8103, MOC8104. CURRENT TRANSFER RATIO. PARAMETER. TEST CONDITION. PART. SYMBOL. MIN. TYP. MAX. UNIT

MOC8101, MOC8102, MOC8103, MOC8104 CURRENT TRANSFER RATIO PARAMETER TEST CONDITION PART SYMBOL MIN TYP MAX UNIT

该数据表的模型线

文件文字版本

MOC8101, MOC8102, MOC8103, MOC8104
www.vishay.com Vishay Semiconductors
CURRENT TRANSFER RATIO
(Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
MOC8101 CTR 50 - 80 % MOC8102 CTR 73 - 117 % Current transfer ratio VCE = 10 V, IF = 10 mA MOC8103 CTR 108 - 173 % MOC8104 CTR 160 - 256 %
SWITCHING CHARACTERISTICS
(Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Turn-on time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω ton - 3.0 - μs Turn-off time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω toff - 2.3 - μs Rise time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω tr - 2.0 - μs Fall time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω tf - 2.0 - μs Cut off frequency fco - 250 - kHz
SAFETY AND INSULATION RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT
Climatic classification According to IEC 68 part 1 55 / 100 / 21 Comparative tracking index CTI 175 Maximum rated withstanding isolation voltage t = 1 min VISO 4420 VRMS Maximum transient isolation voltage VIOTM 10 000 V Maximum repetitive peak isolation voltage VIORM 890 V VIO = 500 V, Tamb = 25 °C RIO ≥ 1012 Ω Isolation resistance VIO = 500 V, Tamb = 100 °C RIO ≥ 1011 Ω Output safety power PSO 400 mW Input safety current ISI 275 mA Input safety temperature TSI 175 °C Creepage distance Standard DIP-6 ≥ 7 mm Clearance distance Standard DIP-6 ≥ 7 mm Creepage distance 400 mil DIP-6 ≥ 8 mm Clearance distance 400 mil DIP-6 ≥ 8 mm Insulation thickness DTI ≥ 0.4 mm
Note
• As per IEC 60747-5-5, § 7.4.3.8.2, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with the safety ratings shall be ensured by means of protective circuits Rev. 1.8, 13-Apr-2023
3
Document Number: 83660 For technical questions, contact: optocoupleranswers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000