Datasheet MAX6701, MAX6701A, MAX6702, MAX6702A, MAX6703, MAX6703A, MAX6704, MAX6705, MAX6705A, MAX6706, MAX6706A, MAX6707, MAX6707A, MAX6708 (Analog Devices) - 2

制造商Analog Devices
描述Low-Voltage, SOT23, µP Supervisors with Power-Fail In/Out, Manual Reset, and Watchdog Timer
页数 / 页12 / 2 — Absolute Maximum Ratings. Electrical Characteristics. PARAMETER. SYMBOL. …
文件格式/大小PDF / 1.2 Mb
文件语言英语

Absolute Maximum Ratings. Electrical Characteristics. PARAMETER. SYMBOL. CONDITIONS. MIN. TYP. MAX. UNITS

Absolute Maximum Ratings Electrical Characteristics PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS

该数据表的模型线

文件文字版本

MAX6701-08/ Low-Voltage, SOT23 µP Supervisors with Power-Fail MAX6701A-03A/ In/Out, Manual Reset, and Watchdog Timer MAX6705A-07A
Absolute Maximum Ratings
VCC ...-0.3V to +6.0V Continuous Power Dissipation (TA = +70°C) Open-Drain RESET, WDO, PFO ..-0.3V to +6.0V 8-Pin SOT23 (derate 8.9mW/°C above +70°C) ..714mW Push-Pull RESET, RESET, WDO, PFO ... -0.3V to (VCC + 0.3V) Operating Temperature Range ... -40°C to +125°C MR, WDI, PFI, RST_IN1, RST_IN2 ... -0.3V to (VCC + 0.3V) Junction Temperature ..+150°C Input Current (VCC) ..20mA Storage Temperature Range .. -65°C to +150°C Output Current (O, WDO) ..20mA Lead Temperature (soldering, 10s) ...+300°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Electrical Characteristics
(VCC = +4.25V to +5.5V for L/M versions, VCC = +2.55V to +3.6V for the T/S/R versions, VCC = +2.1V to +2.75V for the Z/Y versions. TA = -40°C to +125°C, unless otherwise specified. Typical values are at TA = +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
T Operating Voltage Range V A = 0°C to +125°C 1.0 5.5 CC V TA = -40°C to +125°C 1.2 5.5 VCC < 5.5V, no load 12 25 Supply Current MR Unconnected ICC VCC < 3.6V, no load 9 20 µA VCC < 3.6V, no load (MAX6708 only) 6 20 T MAX670_L/MAX670_AL A = -40°C to +85°C 4.50 4.63 4.75 TA = -40°C to +125°C 4.47 4.78 T MAX670_M/MAX670_AM A = -40°C to +85°C 4.25 4.38 4.50 TA = -40°C to +125°C 4.22 4.53 T MAX670_T/MAX670_AT A = -40°C to +85°C 3.00 3.08 3.15 TA = -40°C to +125°C 2.97 3.17 V T CC Reset Threshold A = -40°C to +85°C 2.85 2.93 3.00 (V MAX670_S/MAX670_AS V CC falling) VTH TA = -40°C to +125°C 2.83 3.02 T MAX670_R/MAX670_AR A = -40°C to +85°C 2.55 2.63 2.70 TA = -40°C to +125°C 2.53 2.72 T MAX670_Z/MAX670_AZ A = -40°C to +85°C 2.25 2.32 2.38 TA = -40°C to +125°C 2.24 2.40 T MAX670_Y/MAX670_AY A = -40°C to +85°C 2.12 2.19 2.25 TA = -40°C to +125°C 2.11 2.27 Reset Threshold Temperature Coefficient ∆VTH 60 ppm/°C VCC to Reset Output Delay VCC falling at 10mV/µs 12 µs T Reset Timeout Period t A = -40°C to +85°C 140 200 280 RP ms TA = -40°C to +125°C 120 300 MAX6701(A)/MAX6702(A)/MAX6703(A)/MAX6705(A)/ VCC Falling to WDO Delay 5 µs MAX6706(A)/MAX6707(A) PFI, RST_IN1, RST_IN2 TA = -40°C to +85°C 602 618 634 Threshold VCC = 1.8V to 5.5V mV TA = -40°C to +125°C 593 642 PFI Hysteresis 6 mV www.maximintegrated.com Maxim Integrated │ 2