Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress
Parameter Rating
rating only; functional operation of the device at these or any Supply Voltage ±6 V other conditions above those indicated in the operational Internal Power Dissipation1 650 mW section of this specification is not implied. Exposure to absolute Differential Input Voltage ±6 V maximum rating conditions for extended periods may affect Output Short-Circuit Duration Indefinite device reliability. Storage Temperature Range −65°C to +125°C Operating Temperature Range −40°C to +85°C Lead Temperature (Soldering, 10 sec) 300°C
ESD CAUTION
1 Specification is for device in free air: 8-Lead PDIP Package: θJA = 95°C/W 8-Lead SOIC Package: θJA = 155°C/W 8-Lead MSOP Package: θJA = 200°C/W. Rev. D | Page 7 of 24 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION CONNECTION DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS SINGLE SUPPLY DUAL SUPPLIES BOTH DUAL AND SINGLE SUPPLIES ABSOLUTE MAXIMUM RATINGS ESD CAUTION TYPICAL PERFORMANCE CHARACTERISTICS THEORY OF OPERATION APPLICATIONS INFORMATION BASIC CONNECTION GAIN SELECTION REFERENCE TERMINAL INPUT AND OUTPUT OFFSET VOLTAGE INPUT PROTECTION RF INTERFERENCE GROUNDING Ground Returns for Input Bias Currents Output Buffering Single-Supply Data Acquisition System Amplifying Signals with Low Common-Mode Voltage INPUT DIFFERENTIAL AND COMMON-MODE RANGE vs. SUPPLY AND GAIN OUTLINE DIMENSIONS ORDERING GUIDE