LTC1604 APPLICATIONS INFORMATION CS = RD = 0 tCONV t5 CONVST t6 t8 BUSY t7 DATA (N – 1) DATA N DATA (N + 1) DATA D15 TO D0 D15 TO D0 D15 TO D0 1604 F05 Figure 5. Mode 1a. CONVST Starts a Conversion. Data Outputs Always Enabled(CONVST = ) CS = RD = 0 tCONV t8 t13 t5 CONVST t6 t6 BUSY t7 DATA (N – 1) DATA N DATA (N + 1) DATA D15 TO D0 D15 TO D0 D15 TO D0 1604 F06 Figure 6. Mode 1b. CONVST Starts a Conversion. Data Outputs Always Enabled(CONVST = ) t13 CS = 0 tCONV t8 t5 CONVST t6 BUSY t9 t11 t12 RD t10 DATA N DATA D15 TO D0 1604 F07 Figure 7. Mode 2. CONVST Starts a Conversion. Data is Read by RD 1604fa 10