POWER REQUIREMENTS. The. denotes the specifi cations which apply over the full operating temperature

POWER REQUIREMENTS The denotes the specifi cations which apply over the full operating temperature

该数据表的模型线

文件文字版本

LTC1852/LTC1853
POWER REQUIREMENTS The

denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. (Note 5) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
VDD Analog Positive Supply Voltage (Note 10) ● 2.7 5.5 V OVDD Output Positive Supply Voltage (Note 10) ● 2.7 5.5 V IDD Positive Supply Current VDD = OVDD = 5V, fS = 400kHz ● 2 3 mA VDD = OVDD = 2.7V, fS = 250kHz ● 0.83 1.33 mA PDISS Power Dissipation VDD = OVDD = 5V, fS = 400kHz ● 10 15 mW VDD = OVDD = 2.7V, fS = 250kHz ● 2.25 4 mW IDDPD Power Down Positive Supply Current Nap Mode SHDN = Low, CS = Low 0.5 mA Sleep Mode SHDN = Low, CS = High 20 μA Power Down Power Dissipation VDD = VDD = OVDD = 5V, fS = 400kHz Nap Mode SHDN = Low, CS = Low 2.5 mW Sleep Mode SHDN = Low, CS = High 0.1 mW Power Down Power Dissipation VDD = VDD = OVDD = 3V, fS = 250kHz Nap Mode SHDN = Low, CS = Low 1.5 mW Sleep Mode SHDN = Low, CS = High 0.06 mW
TIMING CHARACTERISTICS The

denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. (Note 5) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
fSAMPLE(MAX) Maximum Sampling Frequency VDD = 5.5V ● 400 kHz VDD = 2.7V ● 250 kHz Acquisition + Conversion VDD = 5.5V ● 2.5 μs VDD = 2.7V ● 4.0 μs tCONV Conversion Time VDD = 5.5V ● 2.0 μs VDD = 2.7V ● 3.5 μs tACQ Acquisition Time (Note 13) ● 150 ns t1 CS to RD Setup Time (Notes 9, 10) ● 0 ns t2 CS to CONVST Setup Time (Notes 9, 10) ● 10 ns t3 CS to SHDN Setup Time (Notes 9, 10) 200 ns t4 SHDN to CONVST Wake-Up Time Nap Mode (Note 10) 200 ns Sleep Mode (Note 10) 10 ms t5 CONVST Low Time (Notes 10, 11) ● 50 ns t6 CONVST to BUSY Delay CL = 25pF 10 ns ● 60 ns t7 Data Ready Before BUSY 20 35 ns ● 15 ns t8 Delay Between Conversions (Note 10) ● 50 ns t9 Wait Time RD After BUSY ● –5 ns t10 Data Access Time After RD CL = 25pF 20 35 ns ● 45 ns CL = 100pF 25 45 ns ● 60 ns t11 BUS Relinquish Time 10 30 ns 0°C to 70°C ● 35 ns – 40°C to 85°C ● 40 ns t12 RD Low Time ● t10 ns 18523fa 5