LTC4309 TheELECTRICAL CHARACTERISTICS l denotes the specifi cations which apply over the full operatingtemperature range, otherwise specifi cations are at TA = 25°C. VCC = 3.3V, VCC2 = 3.3V, unless otherwise noted.SYMBOLPARAMETERCONDITIONSMIN TYP MAX UNITS VTHR(HYST) SDA, SCL Logic Input Threshold Voltage (Note 3) 50 mV Hysteresis CIN Digital Input Capacitance SDAIN, (Note 3) 10 pF SDAOUT, SCLIN, SCLOUT ILEAK Input Leakage Current SDA, SCL, ACC, DISCEN Pins l ±5 μA VOL Output Low Voltage SDA, SCL Pins, ISINK = 4mA, Driven SDA/SCL = 0.2V, VCC = l 0 0.4 V VCC2 = 2.7V 2.7k to VCC on SDA, SCL, Driven SDA/SCL = 0.1V, l 120 170 205 mV VCC = VCC2 = 3.3V VILMAX Buffer Input Logic Low Voltage l 1.2 V Bus Stuck Low Timeout tTIMEOUT Bus Stuck Low Timer SDAOUT, SCLOUT = OV l 25 30 35 ms VOL_FAULT FAULT Output Low Voltage IFAULT = 3mA l 0.4 V IOFF_FAULT FAULT Off Leakage Current l 0.1 ±5 μA Note 1: Stresses beyond those listed under Absolute Maximum Ratings setup and hold times must be adjusted accordingly. Please see the may cause permanent damage to the device. Exposure to any Absolute Operation Section of the datasheet. Maximum Rating condition for extended periods may affect device Note 5: Measure points are 0.3 • VCC and 0.7 • VCC. reliability and lifetime. Note 6: All currents into pins are positive, all voltages are referenced to Note 2: Test performed with connection circuity active. GND, unless otherwise specifi ed. Note 3: Determined by design, not subject to test. Note 7: IPULLUPAC varies with temperature and VCC voltage as shown in the Note 4: For larger equivalent bus capacitance, the skew increases, and Typical Performance Characteristics section. TIMING DIAGRAMSENABLE and READY Timing tPLH_READY tPHL_READY tPLH_EN tPHL_EN ENABLE CONNECT READY 4309 TD01 SDA/SCL Propagation Delays, Rise and Fall Times tRISE tFALL tPLH tPHL tRISE tFALL SDAIN/SCLIN SDAOUT/SCLOUT 4309 TD02 Figure 1. Timing Diagrams 4309fa 4